摘要
以广州某地铁站为背景,介绍了该地铁内部结构,并对该地铁进行了防排烟系统的设计。使用FDS模拟软件,建立了广州某地铁站的模型,并且将地铁站台划分了几个不同区域分别进行模拟对数据进行规划采集。根据广州地铁的建筑结构以及排烟系统方式,在FDS软件中分别设置了两种不同的排烟模式,研究了挡烟垂壁的存在对于地铁火灾烟气控制的影响。
Taking a subway station in Guangzhou as the background,this paper introduces the internal structure of the subway,and designs the smoke control system for the subway. Using FDS simulation software,the model of a subway station in Guangzhou is set up,and the subway platform is divided into several different regions to simulate and collect the data. According to the architectural structure of Guangzhou subway and the way of smoke exhaust system,two different smoke exhaust modes are set up in the FDS software,and the influence of the existence of the vertical wall of the smoke on the smoke control of the subway fire is studied.
作者
李思媛
张宏涛
梁雪
Li Siyuan;Zhang Hongtao;Liang Xue(Col.of Architectural Engineering,North China Univ.of Tech.,Beijing 100144,China)
出处
《山西建筑》
2018年第16期228-230,共3页
Shanxi Architecture
关键词
地铁火灾
模拟分析
排烟模式
subway fire
simulation analysis
smoke exhaust mode