结肠镜下计算机辅助息肉检测系统的构建

Construction of a computer-assisted polyp detection system under colonoscopy
原文传递
导出
摘要 目的构建结肠镜下计算机辅助息肉检测系统,并初步验证其有效性。方法采用基于Faster R-CNN算法,基于开源框架TensorFlow和Faster R-CNN的开源实现,构建结肠镜下计算机辅助息肉检测系统。按训练集大小和难度设置5个试验组:试验1、2、3、4分别含1 000、2 000、4 000、6 000个训练样本,试验5在6 000个训练样本的基础上增加选取难样本的概率。在不同训练集下,计算该系统检测息肉的灵敏度、特异度等分类评价指标及召回率、精确率等目标检测评价指标。结果分类评价指标显示,试验1、2、3、4、5的灵敏度分别为90.1%、93.3%、93.3%、93.3%、93.5%,差异有统计学意义(χ^2=25.324,P〈0.01),试验2、3、4、5的灵敏度均高于试验1,差异均有统计学意义(χ^2=13.964、13.508、13.508、13.386,P均〈0.006 25)。各试验组特异度和阳性预测值的差异均无统计学意义(P均〉0.05)。试验1、2、3、4、5阴性预测值分别为90.4%、93.3%、93.3%、93.3%、93.5%,差异有统计学意义(χ^2=21.862,P〈0.01),试验2、3、4、5的阴性预测值均高于试验1,差异均有统计学意义(χ^2=11.447、11.564、11.755、13.760,P均〈0.006 25)。训练样本量从1 000增加至2 000时,AUC值提升了2%,进一步增加样本至6 000,AUC值提升幅度〈1%,此时保持样本量不变而增加难样本的比例,AUC值又提升了0.4%。目标检测评价指标显示,各试验组召回率分别为73.6%、79.8%、79.5%、79.8%、83.3%,差异有统计学意义(χ^2=71.936,P〈0.01),其中试验2、3、4的召回率均高于试验1,差异均有统计学意义(χ^2=25.960、23.492、25.960,P均〈0.006 25),试验5的召回率高于试验1、2、3、4,差异均有统计学意义(χ^2=67.361、9.899、11.527、9.899,P均〈0.006 25)。试验1、2、3、4、5的精确率分别为87.9%、85.3%、90.2%、91.4%、89.2%,差异有统计学意义(χ^2=48.194,P〈0.01),其中试验3、5的精确率均高于试验2,差异均有统计学意义(χ^2=24.508、15.223,P均〈0.006 25),试验4的精确率高于试验1、2,差异均有统计学意义(χ^2=13.524、39.120,P均〈0.006 25)。随着样本数量增多和训练难度加大,对应的F1分数和平均精度均值均稳步上升。结论本研究初步构建了结肠镜下计算机辅助息肉检测系统,目前灵敏度最高可达93.5%,召回率最高可达83.3%。增大训练集可一定程度上提升息肉检测成绩,但会到达一个瓶颈,此时适当增加训练难度,可进一步提升检测成绩,尤其是召回率。 ObjectiveTo set up a computer-assisted polyp detection system under colonoscopy, and to preliminarily verify its effectiveness.MethodsBased on Faster R-CNN algorithm and the open source implementation of the open source framework tensorflow and Faster R-CNN, a computer-assisted polyp detection system under colonoscopy was constructed. According to the size and difficulty of the training set, five test groups were set up: test group one, two, three and four contained 1 000, 2 000, 4 000 and 6 000 training samples, respectively. Test group five increased the probability of selecting the difficult samples based on 6 000 training samples. In different training sets, the sensitivity, specificity, other classification evaluation parameters, and the evaluation parameters of target detection such as recall and precision of this polyps detection system were calculated.ResultsClassification evaluation parameters showed that the sensitivities of test group one, two, three, four and five were 90.1%, 93.3%, 93.3%, 93.3% and 93.5%, respectively, and the difference was statistically significant (χ^2=25.324, P〈0.01). The sensitivities of test group two, three, four and five were all higher than that of test group one, and the differences were statistically significant (χ^2=13.964, 13.508, 13.508 and 13.386, all P〈0.006 25). There were no significant differences in specificity and positive predictive value among test groups (both P〉0.05). The negative predictive values of test group one, two, three, four and five were 90.4%, 93.3%, 93.3%, 93.3% and 93.5%, respectively, and the differences were statistically significant (χ^2=21.862, P〈0.01). The negative predictive values of test group two, three, four and five were higher than that of test group one, and the differences were statistically significant (χ^2=11.447, 11.564, 11.755, 13.760; all P〈0.006 25). As the training sample size increased from 1 000 to 2 000, the area under curve (AUC) increased by 2%, and further increased the sample size to 6 000, AUC increased by less than 1%. At this point maintaining the same sample size while increasing the proportion of difficult samples, AUC increased by 0.4%. The results of evaluation parameters of target detection showed that the recall rate of each test group was 73.6%, 79.8%, 79.5%, 79.8% and 83.3%, respectively, and the differences were statistically significant (χ^2=71.936, P〈0.01). Among them, the recall rates of test group two, three and four were higher than that of test group one, and the differences were statistically significant (χ^2=25.960, 23.492 and 25.960, all P〈0.006 25), and the recall rate of test group five was higher than those of test group one, two, three and four, and the differences were statistically significant (χ^2=67.361, 9.899, 11.527 and 9.899; all P〈0.006 25). In addition, the precision rates of test group one, two, three, four and five were 87.9%, 85.3%, 90.2%, 91.4% and 89.2%, respectively, and the difference was statistically significant (χ^2=48.194, P〈0.01). The precision rates of test group three and five were higher than that of test group two, and the differences were statistically significant (χ^2=24.508 and 15.223, both P〈0.006 25), and the precision rate of test group four was higher than those of test group one and two, and the differences were statistically significant (χ^2=13.524 and 39.120, both P〈0.006 25). As samples size and training difficulty increased, the values of F1-score and mean average precision increased steadily.ConclusionsThis study initially constructed a computer-assisted polyp detection system under colonoscopy. Currently the maximum sensitivity reached 93.5%, and the maximum recall rate reached 83.3%. Increasing the training set size may improve the polyp detection result to a certain degree, however it will reach a bottleneck. At this time, increasing the training difficulty can further improve the detection scores, especially the recall rate.
作者 孙菁 贺新珏 张洁 徐磊 桑建忠 毛鑫礼 陈强 叶丽萍 周建波 丁小云 顾青 陈洪潭 章宏 陈李华 许国强 季峰 厉有名 虞朝辉 Sun Jing;He Xinjue;Zhang Jie;Xu Lei;Sang Jianzhong;Mao Xinli;Chen Qiang;Ye Liping;Zhou Jianbo;Ding Xiaoyun;Gu Qing;Chen Hongtan;Zhang Hong;Chen Lihua;Xu Guoqiang;Ji Feng;Li Youming;Yu Chaohui(Department of Gastroenterology,Ruijin Hospital,School of Medicine,Shanghai Jiao Tong University,Shanghai 200025,Chin;Department of Gastroenterology,The First Affiliated Hospital,Zhejiang University,Hangzhou 310003,Chin)
出处 《中华消化杂志》 CAS CSCD 北大核心 2018年第7期473-478,共6页 Chinese Journal of Digestion
关键词 结肠镜 计算机辅助息肉检测 分类评价指标 目标检测评价指标 Colonoscopes Computer-assisted polyp detection Classification evaluation indexes Target detection evaluation indexes
  • 相关文献

参考文献1

二级参考文献9

  • 1Jemal A. Simard KP. Dorell C, el al. Annual repori to thenation on the status of cancer. 1975—-2009,featuring theburden and trends in Human papillomavirus ( HPV) -associatedcancers and HPV vaccination coverage levels[J]. J Natl CancerInsi, 2013,105C3):175-201.
  • 2Shah HA,Paszat LF,Saskin R. et al. Factors associated withincomplete colonoscopy: a population-based study [ J ].Ciastroenterology, 2007 . 132(7):2297-2303.
  • 3Karcaaltincaha M. Karaosmanoglu D. Akata I),el al. Dual energyvirtual CT colonoscopy with dual source computed tomography:initial experience[J]. Rofo, 2009.181(9) :859-862.
  • 4Kealey SM, I)odd JO. MacEneaney PM. et al. Minimalpreparation computed tomography instead of barium enemacolonoscopy for suspected colon cancer in frail elderly patients: anoutcome analysis study[J]. ('lin Radiol. 2004*59(1) :44-52.
  • 5Boellaard TN, Henneman ()1), Strcekstra (;J, et al. Thefeasibility of colorectal cancer detection using dual energycomputed tomography with iodine map!)ing[J]. Clin Radiol.2013,68(8):799-806.
  • 6Zalis ME. Blake MA. Cai W, et al. Diagnostic accuracy oflaxative-free computed tomographic colonography for detectionof adenomatous polyps in asymptomatic adults: a prospectiveevaluationfJl. Ann Intern Med, 2012,156(10):692-702.
  • 7Pickhardt PJ. Hassan C. Halligan S, et al. Colorectal cancer: C'Tcolonography and colonoscopy for detection—systematic review andmeta-analysis[J], Radiology, 2011.259(2) :393-405.
  • 8cle Haan MC',van (xelder RE, (iraser A,et al. Diagnosticvalue of CT-colonography as compared to colonoscopy in anasymptomatic screening population: a meta-analysis[J ]. KurRadiol, 2011,21(8): 1747-1763.
  • 9丁忠,陆风旗,张雷,张追阳,王均庆.多排螺旋CT检查在结肠癌诊断中的临床价值[J].中华消化外科杂志,2014,13(12):983-987. 被引量:42

共引文献6

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部