期刊文献+

台风导致的水库原水水质突变及其应对措施 被引量:3

Reservoir Raw Water Quality Mutation Caused by Typhoon and Its Response Measures
原文传递
导出
摘要 以宁波市某净水厂为例,研究了因台风导致的水库原水水质突变的过程,发现由台风引发的暴雨主要对水库原水的浊度、色度、氨氮、CODMn、铁、锰、微生物指标等产生影响,其中浊度是水质控制的重点;在强降雨开始对原水水质产生影响之后的36 h是水质控制的重点时间段,强化混凝是控制出厂水各项指标稳定达标的关键。 Taking a water treatment plant in Ningbo City as an example, the process of reservoir raw water quality mutation caused by the typhoon was investigated. It was found that the rainstorm caused by typhoons mainly affected the turbidity, chromaticity, ammonia nitrogen, CODMn, iron, manganese and microbial indexes of the raw water, and turbidity was a key index to be controlled. 36 hours after heavy rainfall began to affect raw water quality was the key period for water quality controlling. Enhanced coagulation was the key step for all the indexes to stably meet the standard in the water treatment plant.
作者 周正协 何建荣 虞静静 刘志刚 陈卫 ZHOU Zheng-xie;HE Jian-rong;Yu Jing-jing;LIU Zhi-gang;CHEN Wei(Ningbo Water Supply Co.Ltd.,Ningbo 315041,China;College of Environment,Hohai University,Nanjing 210098,China)
出处 《中国给水排水》 CAS CSCD 北大核心 2018年第15期35-38,43,共5页 China Water & Wastewater
基金 宁波市科技服务示范项目(2017F10011)
关键词 水库原水 水质突变 浊度 强化混凝 reservoir raw water water quality mutation turbidity enhanced coagulation
  • 相关文献

参考文献3

二级参考文献20

共引文献52

同被引文献37

引证文献3

二级引证文献4

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部