期刊文献+

非均匀环境中足部供暖对人体整体与局部热感觉的影响 被引量:6

Influences of foot heating on human body's overall and local thermal sensation in non-uniform environment
下载PDF
导出
摘要 对20名受试者采用问卷调查的方式,研究了14,16,18℃环境温度下足部供暖对人体整体与局部热感觉的影响。结果显示:足部供暖不仅能增大足部热感觉投票值,还能显著增大大腿、小腿以及整体热感觉投票值(P<0.05);在均匀环境下,足部热感觉投票值与大腿、小腿热感觉投票值具有较强线性相关性(R^2≥0.94),与整体热感觉投票值也呈线性关系(R^2=0.89);在非均匀环境下,足部热感觉投票值与大腿、小腿以及整体热感觉投票值呈高斯函数曲线相关关系(R2分别为0.94,0.92,0.83)。 With a questionnaire survey on 20 volunteers, studies the effects of foot heating on human body's overall and local thermal sensation at 14℃, 16℃, 18℃ of ambient temperature respectively. The results show that foot heating can not only increase the thermal sensation vote value of the feet, but also significantly increase the thigh, shank and overall thermal sensation vote values(P〈0.05). In a uniform environment, the thermal sensation vote value of the feet has a strong linear correlation (R^2≥0.94) with those of the thigh and shank, and also has a linear relationship with the overall thermal sensation vote value (R^2 = 0.89). In a non-uniform environment, the relationship between the foot thermal sensation voting value and the thigh, shank and overall thermal sensation vote values is the Gauss function curve (R^2 is 0.94, 0.92, 0.83, respectively).
作者 谭畅 李念平 何颖东 Tan Chang;Li Nianping;He Yingdong
机构地区 湖南大学
出处 《暖通空调》 2018年第8期35-41,共7页 Heating Ventilating & Air Conditioning
基金 "十三五"国家重点研发计划项目"长江流域建筑供暖空调解决方案和相应系统"(编号:2016YFC0700303 2016YFC0700306)
关键词 非均匀环境 足部供暖 整体热感觉 局部热感觉 拟合分析 non-uniform environment foot heating overall thermal sensation local thermal sensation fitting analysis
  • 相关文献

参考文献3

二级参考文献41

  • 1Burch S D, Pearson J T, Ramadhyani S. Experimental study of passenger thermal comfort in an automobile under severe winter conditions[G]/// ASHRAE Trans, 1991, 97(1): 239-246.
  • 2Hagino M, Hara J. Development ofa method for predicting comfortable airflow in the passenger compartment[G]//SAE Technical Paper Series. New York: Society of Automotive Engineers, 1992.
  • 3Hodder S G, Loveday D L, Parsons K C, et al. Thermal comfort in chilled ceiling and displacement ventilation environments: vertical radiant temperature asyrmnetry effects[J]. Energy and Buildings, 1998, 27(2) : 167-173.
  • 4Melikov A K, Arakelian R S, Halkjaer L, et al. Spot cooling part 1 : human responses to cooling with air jets[G]//ASHRAE Trans, 1994, 100(2):476- 499.
  • 5Zhang Y, WyonD P, Fang L, et al. The influence of heated or cooled seats on the acceptable ambient temperature range [J]. Ergonomics, 2007, 50(4): 586- 600.
  • 6Melikov A K. Personalized ventilation [J]. Indoor Air, 2004, 14 (7): 157-167.
  • 7Gong N, Tham K W, Melikov A K. Human perception of local air movement and the acceptable air velocity range for local air movement in the tropics [C]//Proceedings of Indoor Air 2005. Beijing, 2005: 452-457.
  • 8Berglund L G. Thermal acceptability [G]// ASHRAE Trans, 1979, 85(2):825-834.
  • 9Gagge A P, Nevins R G. Effect of energy conservation guideline on comfort, acceptability and health[R]. Final report of contract # CO-04-51891- 00. USA: Federal Energy Administration, 1976.
  • 10Berglund L G, Gonzalez R R. Application of acceptable temperature drifts to built environments as a mode of energy conservation[G]// ASHRAE Trans, 1978, 84(1): 110-121.

共引文献24

同被引文献19

引证文献6

二级引证文献12