期刊文献+

PET/MR的衰减校正技术 被引量:2

Overview of PET/MR attenuation correction
原文传递
导出
摘要 PET/MR是目前最先进的分子影像设备,PET图像需要通过衰减校正来得到真实的放射性药物活度分布并对其进行量化。笔者主要对PET/MR的衰减校正原理和衰减校正的方法进行综述,重点介绍地图集法、组织分割法和具有发展前景的发射数据重建法。 PET/MR is the most advanced molecular imaging device nowadays. The PET image needs to be quantified by attenuation correction(AC) to obtain the real activity distribution of radioactive drugs. The principle of AC of PET/MR and four methods of AC are briefly described in this paper .This paper mainly introduces the tissue segmentation and atlas method. A more promising launch data reconstruction method is also introduced in this paper.
作者 陈兴 赵军 Chen Xing;Zhao Jun(Department of Nuclear Medicine,Shanghai East Hospital,Tonal University,Shanghai 200123,China)
出处 《国际放射医学核医学杂志》 2018年第4期352-356,共5页 International Journal of Radiation Medicine and Nuclear Medicine
关键词 正电子发射型计算机断层显像 磁共振成像 衰减校正 地图集法 组织分割法 发射数据重建法 Positron emission computed tomography Magnetic resonance imaging Attenuationcorrection Atlas Tissue segmentation Emission data reconstruction
  • 相关文献

参考文献3

二级参考文献42

  • 1Visvikis D,Monnier F,Bert J,et al.PET/MP- attenuation correction: where have we come from and where are we going?Lll.Eur J Nucl Med Mol Imaging,2014,41(6):1172-1175.
  • 2Burger C,Goerres G,Schoenes S,et al.PET attenuation coefficients from CT images: experimental evaluation of the transformation of CT into PET 511-kev attenuation coefficients[J].Eur J Nucl Med Mol Imaging,2002,29(7):922-927.
  • 3Visvikis D,Costa DC,Croasdale I,et al.CT based attenuation correction in the calculationof semi-quantitative indices of 18FDG uptake in PET[J].Eur J Nucl Med Mol Imaging,2003, 30(3):344-353.
  • 4Huang SC,Carson RE,Phelps ME,et al.A boundary method for attenuation correction in positron computed tomographyL1].J Nucl Med,1981,22(7):627-637.
  • 5Zaidi H,Montandon ML,Slosman DO.Magnetic resonance imaging-guided attenuation and scatter corrections in three-dimensional brain positron emission tomography[J].Med Phys, 2003,30(5) :937 -948.
  • 6Rota Kops E,Wagenknecht G,Scheins J,et al.Attenuation correction in MR-PET scanners with segmented Tl-weighted M1K images[J].IEEE Nucl Sci Conf R,2009:2530-2533.
  • 7Wagenknecht G,Rota Kops E,Tellmann L,et al.Knowledge- based segmentation of attenuation-relevant regions of the head in TI-weighted MR images for attenuation correction in MR/ PET systems[J].IEEE Nucl Sci ConfR,2009:3338-3343.
  • 8Wagenknecht G, Rota Kops E, Kaffanke J,et al.CT-based evaluation of segmented head regions for attenuation correction in MR-PET systems[J].IEEE Nuci Sci ConfR,2010:2793-2797.
  • 9Wagenknecht G,Rota Kops E,Mantlik F,et al.Attenuation correction in MiL-Brain PET with segmented Tl-weighted MR.images of the patient's head: a comparative study with CT[J].IEEE Nucl Sci ConfR,2(}l 1:2261-2266.
  • 10Malone IB,Ansorge RE,Williams GB,et al.Attenuation correction methods suitable for brain imaging with a PET/MRI Scanner: a comparison of tissue atlas and template attenuation map approaches[J].J Nucl Med,2011,52(7):1142-1149.

共引文献9

同被引文献16

引证文献2

二级引证文献2

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部