在城市道路照明施工图设计时,由于对照明标准值的概念、功率密度的计算方法、道路照明低压电缆敷设及线路保护的特点等内容认识不够清晰,会出现表述不清、不满足规范条文,甚至违反强条的现象。针对城市道路照明施工图审查中常见的问题,结合现行规范和标准,对上述现象逐一进行了分析说明,并给出了解决方法,可供类似工程参考和借鉴。
Owing to the insufficient content knowledge in the concept of lighting standard value, the calculation method of power density, the low-voltage cable installation of road lighting and the characteristics of line protection, there will be unclear expression, not meeting the specifications, or even violation of strong provisions in the design of the construction drawings for urban road lighting. Aiming at the problemscommonly existing in the review of the construction drawings for the urban road lighting, and combined with the current codes and standards, the article analyzes and explains the above problems, and gives the solving methods, which can be referred for the similar projects.
出处
《城市道桥与防洪》
2018年第8期342-344,共3页
Urban Roads Bridges & Flood Control
关键词
道路照明
照明标准值
功率密度
线路敷设
线路保护
隧道LED照明频闪
road lighting
standard value of lighting
power density
line laying
line protection
tunnel
LED
lighting stroboflash