摘要
阐述了三相五柱式双反星形整流变压器的适用条件和技术特点,说明了三相五柱式双反星形整流变压器网侧和阀侧容量不相等的原因和五柱式铁心代替平衡电抗器的原因。
The applicable condition and technical characteristics of three-phase five-column double reverse star type rectifier transformer are expounded. The reason of un- equal capacity between network side and valve side of the three-phase five-column double reverse star type rectifier transformer and the reason that five-column core re- places balanced reactor are explained.
作者
李永新
刘建华
唐明珠
LI Yong-xin;LIU Jian-hua;TANG Ming-zhu(Shanghai Nanqiao Transformer Co.,Ltd.,Shanghai 201400,China)
出处
《变压器》
北大核心
2018年第8期1-5,共5页
Transformer
关键词
整流变压器
三相五柱
双反星形
设计
Rectifier transformer
Three-phase five-column
Double reverse star type
Design