期刊文献+

Investigation of SPECT/CT cardiac imaging using Geant4

Investigation of SPECT/CT cardiac imaging using Geant4
下载PDF
导出
摘要 The purpose of this paper is to propose a friendly computational framework able to investigate particles tracking through different compartments of the human being using dedicated numerical techniques.The main building blocks of this framework are:(i) convenient X-ray spectra calculator for different filter/anode combination,(ii) realistic voxelized computational human phantom,(iii)validated Geant4-based Monte Carlo simulation,and(iv)extendable and free image processing software.We studied the multimodality SPECT/CT cardiac imaging using specific spectrum of the ^(99m)Tc and 120 kVp X-ray beam,for internal and external exposure,respectively.The application of the framework to quantify the loss of information between combined and simultaneous coregistration was carried out.Two main objectives were addressed:(i) an ideal geometry was simulated for educational purposes(ii) a realistic case study was carried out,for research purposes,concerning the modeling of the GE Infinia II 3/800 Gamma Camera.We compared the effect of using a Na I(Tl) and CZT crystal detector,and a LEHR and MEGP collimator with different uptake values of the heart organ(1:1,5:1 and 50:1) for both simultaneous andcombined SPECT/CT images.We confirmed the usefulness of the Na I(Tl) crystal with the LEHR collimator for such kind of study. The purpose of this paper is to propose a friendly computational framework able to investigate particles tracking through different compartments of the human being using dedicated numerical techniques. The main building blocks of this framework are: (i) convenient X-ray spectra calculator for different filter/anode combination, (ii) realistic voxelized computational human phantom, (iii) validated Geant4-based Monte Carlo simulation, and (iv) extendable and free image processing software. We studied the multimodality SPECT/CT cardiac imaging using specific spectrum of the 99mTc and 120 kVp X-ray beam, for internal and external exposure, respectively. The application of the framework to quantify the loss of information between combined and simultaneous coregistration was carried out. Two main objectives were addressed: (i) an ideal geometry was simulated for educational purposes (ii) a realistic case study was carried out, for research purposes, concerning the modeling of the GE Infinia Ⅱ 3/8" Gamma Camera. We compared the effect of using a NaI(T1) and CZT crystal detector, and a LEHR and MEGP collimator with different uptake values of the heart organ (1:1, 5:1 and 50:1) for both simultaneous andcombined SPECT/CT images. We confirmed the usefulness of the NaI(T1) crystal with the LEHR collimator for such kind of study.
出处 《Nuclear Science and Techniques》 SCIE CAS CSCD 2018年第7期198-208,共11页 核技术(英文)
基金 Supported by the College of Applied Medical Sciences Research Centre and the Deanship of Scientific Research at King Saud University of Saudi Arabia
关键词 GEANT4 成像 心脏 图象处理软件 计算框架 蒙特卡罗模拟 现实主义 GAMMA Geant4 Voxel Phantom X-ray generator Multimodality imaging

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部