期刊文献+

风电场无功电压控制系统运行现状分析及提升措施 被引量:12

Operation Situation Analysis and Improvement Measures for Automatic Voltage Control System of Wind Farms
下载PDF
导出
摘要 风电场无功电压控制策略、各分系统间通信、单体设备性能等各个环节都将影响场站无功电压控制性能。依据某千万千瓦级风电基地近三年来的实际运行数据及现场检测数据,首先分析了风电场无功电压控制系统现状,系统介绍了目前无功电压控制系统架构及常用控制策略;其次从场站无功电压控制流程入手,阐明了影响场站无功电压控制性能的关键因素;最后形成了提升风电场无功电压控制性能及运行水平的措施,并进行了实例验证。 The control strategy of automatic voltage, the communication between systems and the performance of single device affect the performance of the reactive power and voltage control of wind farms. Based on the actual operation data and field testing data of a ten-million-kilowatts wind power base in the past three years, the paper firstly analyzes the status of the wind farm automatic voltage control (AVC) system, and systematically introduces the current AVC system architecture and conventional control strategies; and then it clarifies hhe key factors affecting the wind farm AVC performance from the wind farm AVC process. Finally, some measures are proposed for improving the wind farm AVC performance and operation level, and are verified by case study.
作者 刘京波 宋鹏 吴林林 柳玉 吴宇辉 张扬帆 LIU Jingbo1,2, SONG Peng1,2, WU Linlin1,2, LIU Yu1,2, WU Yuhui1,2, ZHANG Yangfan1,2(1. State Grid Jibei Electric Power Co.,Ltd. Research Institute (North China Electric Power Research Institute Co.,Ltd.) Beijing 100045, China; 2. Grid-connected Operation Technology for Wind-Solar-Storage Hybrid System State Grid Corporation Key Laboratory, Beijing 100045, China)
出处 《中国电力》 CSCD 北大核心 2018年第8期130-138,共9页 Electric Power
基金 国家电网公司科技项目(52018K170028)~~
关键词 风电场 无功电压 控制系统 系统响应时间 电压灵敏度 wind farm automatic voltage control system system response time voltage-sensitivity
  • 相关文献

参考文献22

二级参考文献197

共引文献923

同被引文献138

引证文献12

二级引证文献60

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部