摘要
为了解决闭式系统地铁站中传统通风空调系统存在的主要问题,如冷却塔扰民、冷水机组机房占地面积大、投资高、耗电量大、运行费用高等,系统分析闭式系统地铁站的特点,提出隧道嵌装式全工况空调系统,为闭式系统地铁站通风空调系统提供安全环保、高效节能、集成简约的解决方案。
In order to solve the main problems of the traditional ventilation and air-conditioning system in the closed system subway station,such as the cooling tower disturbing people,the large area of the water chiller room,high investment,high power consumption and high operating cost,the systematic analysis on the characteristics of the closed system subway station is conducted. The tunnel embedded air-conditioning system is proposed,which provides a safe,environmentally protection,high-efficient energy-saving,integrated simple solution for the closed system subway station ventilation and air-conditioning system.
作者
王亮添
黄云材
黄国斌
李迎春
Wang Liangtian;Huang Yuncai;Huang Guobin;Li Yingchun(Guangdong Shenling Environment Systems Co.,Ltd)
出处
《制冷与空调》
2018年第7期55-58,共4页
Refrigeration and Air-Conditioning
关键词
通风空调
闭式系统
地铁站
节能
ventilation and air conditioning
closed type system
subway station
energy saving