摘要
本文针对核电厂目前尚未解决的问题"在失去四级电源工况下1号冷冻机和3号冷冻机无法正常启动"进行分析,提出解决方案并进行全面验证,确保冷冻机能够长期稳定运行。
The unsolved problem of the nuclear power plant,which is the refrigerator No.1 and refrigerator No.3 couldn't start normally without Level 4 of Qilie-Power was analyzed.The solution was proposed and verified comprehensively to ensure that the refrigerator can run stably for a long time.
作者
臧小军
吴海燕
秘双虎
贾晓琼
ZANG Xiaojun;WU Haiyan;MI Shuanghu;JIA Xiaoqiong(China Nuclear Power Management Co.,LTD,Jiaxing 314000,China)
出处
《电工技术》
2018年第12期104-105,共2页
Electric Engineering
关键词
冷冻机
故障分析
refrigerator
failure analysis