Upgrade of the X-ray pinhole camera system at SSRF

Upgrade of the X-ray pinhole camera system at SSRF
下载PDF
导出
摘要 An X-ray pinhole camera has been used to determine the transverse beam size and emittance on the diagnostic beam line of the storage ring at SSRF since2009.The performance of the beam size measurement is determined by the width of the point spread function of the X-ray pinhole camera.Beam-based calibration was carried in 2012 out by varying the beam size at the source point and measuring the image size.However,this calibration method requires special beam conditions.In order to overcome this limitation,the pinhole camera was upgraded and an X-ray quasi-monochromator was installed.A novel experimental method was introduced by combining the pinhole camera with the monochromator to calibrate the point spread function.The point spread function can be accurately resolved by adjusting the angle of the monochromator and measuring the image size.The X-ray spectrum can also be obtained.In this work,the X-ray quasi-monochromator and the novel beam-based calibration method will be presented in detail. An X-ray pinhole camera has been used to determine the transverse beam size and emittance on the diagnostic beam line of the storage ring at SSRF since2009.The performance of the beam size measurement is determined by the width of the point spread function of the X-ray pinhole camera.Beam-based calibration was carried in 2012 out by varying the beam size at the source point and measuring the image size.However,this calibration method requires special beam conditions.In order to overcome this limitation,the pinhole camera was upgraded and an X-ray quasi-monochromator was installed.A novel experimental method was introduced by combining the pinhole camera with the monochromator to calibrate the point spread function.The point spread function can be accurately resolved by adjusting the angle of the monochromator and measuring the image size.The X-ray spectrum can also be obtained.In this work,the X-ray quasi-monochromator and the novel beam-based calibration method will be presented in detail.
出处 《Nuclear Science and Techniques》 SCIE CAS CSCD 2018年第8期170-178,共9页 核技术(英文)
基金 supported by the National Science Foundation of China(No.11375255)
关键词 照相机系统 X光检查 SSRF 针孔 尺寸测量 刻度方法 传播函数 单位面积 X-ray pinhole camera Transverse beam size Diagnostic beam line Point spread function X-ray quasi-monochromator
  • 相关文献

参考文献2

二级参考文献10

  • 1冷用斌,周伟民,陈永忠,赵国璧,余俊,刘德康.上海光源储存环直流流强监测系统设计[J].核技术,2007,30(6):477-480. 被引量:4
  • 2Thomas C A, Rehm G. An X-ray pinhole camera system for diamond, DIPAC2005, 2005.93-95.
  • 3Bergstrom J C, Vogt J M. Nucl Instrum Methods Phys Res Section A, 2008, 587(2): 441-457.
  • 4Corbett J, Cheng W. lnterferometer beam size measurements in SPEAR3, PAC2009.
  • 5Thomas C, Rehm G. Phys Rev ST Accel Beams, 2010, 13(2): 022805.
  • 6Elleaume P, Fortgang C. J Synchrotron Rad, 1995, 2(5): 209-214.
  • 7Thomas C A, Rehm G An X-ray Pinhole Camera System for DIAMOND[C]. DIPAC2005, 93-95.
  • 8Bergstrom J C, Vogt J M. The X-ray diagnostic beamline at the Canadian Light Source[J]. Nucl Instrum Methods Phys Res Sect A, 2008, 587(2): 441-457.
  • 9Elleaume P, Fortgang C. Measuring beam sizes and ultra-small electron emittances using an X-ray pinhole camera[J]. J Synchrotron Rad, 1995, 2(5): 209-214.
  • 10黄国庆,陈杰,陈之初,冷用斌,叶恺容.上海光源储存环X-ray针孔相机系统设计[J].核技术,2010,33(11):806-809. 被引量:5

共引文献4

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部