摘要 通过分析国家标准的具体试验要求,提出测试装置设计原理及技术指标,研制了一种新的断路器接线端子弯曲及拉出试验的测试装置,拉力值和试验时间可设定,实现拉力逐渐增大到规定值,并自动保持恒定输出,更加符合标准所规定拉力不能突加的要求。以剩余电流断路器为试验样品,按试验流程实测接线端子的弯曲及拉出试验,验证了新型测试装置的功能及可靠性。最后对该测试装置的测量结果不确定因素进行溯源,取拉力量值为代表开展测量结果不确定度评定与分析。 This paper analyzed the requirements of the national standard,developed a new test device for circuit breaker terminal bending and pullout test,tensile force value and the test time can be set to achieve the tension increased to a specified value,and automatically maintain a constant output,being more in line with the standards of pull not sudden requirements. The function and reliability of the new test device were verified by the test of bending and pulling out of the circuit breaker. Finally,the uncertainty of the measurement results of the test device was analyzed,and the uncertainty of the measurement result was evaluated by the pull force value.
作者 苏金州 陈金汕 SU Jinzhou;CHEN Jinshan(University of Fuzhou,Fuzhou 350108,China;Fujian Inspection and Research Institute for Product Quality,Fuzhou 350002,China)
出处 《电器与能效管理技术》 2018年第13期64-69,74,共7页 Electrical & Energy Management Technology
关键词 断路器 接线端子 弯曲试验 拉出试验 自动保持拉力恒定 不确定度评定 circuit breaker terminal bend test pull out test keep the tension constant automatically uncertainty
  • 相关文献

参考文献6

二级参考文献41

  • 1吴何畏.材料试验机的升级改造[J].机床与液压,2007,35(2):142-145. 被引量:8
  • 2王宏利,程旭德,徐兵,郑源.基于AT89C51的智能测频仪设计[J].计算机测量与控制,2007,15(3):410-412. 被引量:10
  • 3刘九卿.剪切式力与称重传感器的力学基础[J].衡器,1997(2):13-20. 被引量:8
  • 4黄新波,孙钦东,程荣贵,张冠军,刘家兵.导线覆冰的力学分析与覆冰在线监测系统[J].电力系统自动化,2007,31(14):98-101. 被引量:149
  • 5云南电网公司曲靖供电局.曲靖电网2008年冰灾受损输电线路分析:110-500kV[M].昆明:云南科技出版社,2009.
  • 6中国南方电网公司.电网防冰融冰技术及应用[M].北京:中国电力出版社,2010.
  • 7Alavie A T, Maaskant R, Ohn M M, et al. Application and characterization of intracore grating sensors in a cfrp prestressed concrete girder[C]//Smart Stractures and Materials. Orlando, FL, USA: [s. n. ], 1994.
  • 8MA Guo ming, LI Cheng-rong, MENG Chen-ping, et al. Icemonitoring on overhead transmission lines with FBG tension sensor[C] // Power and Energy Engineering Conference (AP PEEC). Chengdu, China: [s. n. ], 2010.
  • 9DL/T5092-1999 110-500kV架空送电线路设计技术规程[s],2003.
  • 10JJF1059-1999.测量不确定度评定与表示.[S].国家质量技术监督局发布,1999-05-01实施..