摘要
利用自制模型在室内进行一维电渗试验,通过4组试验对比研究不同通断比的间歇通电模式对电渗加固滩涂淤泥的影响.通过对比试验过程中的排水量、抗剪强度、含水率、电极腐蚀强度表明:间歇通电可有效减缓电极腐蚀,改善土体抗剪强度,提高电渗效果;间歇周期不宜过长,建议通电2 h间歇15 min.
Four laboratory tests for soft clay in the shape under intermittent current were conducted on electro-osmotic consolidation apparatus developed by authors. Currents and drainageswere monitored every certain time during the test,while the distributions of shear strength and water content weremeasured after the test. The results suggest that with appropriate power on period and time ratio,current intermittence can result in lighter electrode corrosion and enhance electro-osmosis efficiency excessively,with the optimal power on and off period being 2 h and 15 min respectively.
作者
金锦强
陈晨
章迪康
林海志
海钧
JIN Jin-qiang1, CHEN Chen2, ZHANG Di-kang3, LIN Hai-zhi4,HAI Jun5(1. Wenzhou Oufei Development and Construction Investment Group Limited, Wenzhou 325000, China; 2. College of Architecture and Mapping, Jiangxi University of Science and Technology, Ganzhou 341000, China; 3. Zhejiang Industry and Trade Polytechnic, Wenzhou 325035, China; 4. South Zhuangyuan Construction and Development LTD. CO. , Dongtou County, Wenzhou 325035, China; 5. College of Architecture and Civil Engineering,Wenzhou University, Wenzhou 325035, China)
出处
《浙江水利水电学院学报》
2018年第3期22-26,共5页
Journal of Zhejiang University of Water Resources and Electric Power
关键词
间歇通电
通电周期
通断比
current intermittence
power on period
time ratio of power on and off