摘要
特高频法因其抗干扰能力强,检测效率高,检测灵敏度高等优点,成为被广泛用作GIS带电检测的主要手段。阐述了在GIS设备中运用特高频法检测的原理和定位方法,结合某内部绝缘缺陷的案例对检测分析和定位过程进行详细介绍,提出了判别缺陷类型的方法和策略,可为相关工作提供参考。
Ultra-high frequency(UHF) method is widely used as the main means of live detection for GIS equipment due to its strong anti-interference ability, high detection efficiency and sensitivity. In this paper, the UHF detecting principle and locating method were discussed. Combined with a typical case of internal insulation defect,this paper introduced the application of UHF method in detail to detect and locate partial discharge for GIS and put forward strategies to distinguish defect types, which can provide references for related work.
作者
李鲁博
王荣亮
宋晓博
LI Lubo;WANG Rongliang;SONG Xiaobo(State Grid Tianjin Electric Power Maintenance Company,Tianjin 300000,China;State Grid Tianjin Electric Power Research Institute,Tianjin 300000,China)
出处
《山西电力》
2018年第2期17-21,共5页
Shanxi Electric Power
关键词
局部放电
带电检测
特高频
partial discharge(PD)
live detection
ultra-high frequency(UHF)