摘要
某石化企业炼油装置原油输送泵振动严重超标,通过现场勘察、振动测点的选择和泵工作状态下振动测试仪对振动信号的频谱分析,找出引起泵振动超标的主要原因,制订检修方案和改造措施,实施后取得了良好的效果。
The vibration of a crude oil delivery pump of a petroleum refinery has exceeded the standard seriously.Through on-site investigation,selection of measurement points for vibration,and spectrum analysis of the vibration signal by a vibration tester under the working state of the pump,the main causes of pump vibration exceeding the standard were identified and repaired.The plan and reform measures have achieved good results after implementation.
作者
陈进
Chen Jin(Chemical Division,SINOPEC Shanghai Petrochemical Co.,Ltd.,Shanghai 20054)
出处
《石油化工技术与经济》
2018年第3期30-34,共5页
Technology & Economics in Petrochemicals
关键词
双吸泵
振动
频谱分析
改造措施
double suction pump
vibration
spectrum analysis
reform measures