文章针对CAWS600型自动气象站出现的一次监控界面无数据显示的故障,从采集监控软件、电源系统、通信系统等方面对故障产生原因进行了分析,并提出了相应的排除方法、检测流程和解决措施,为其它台站提供借鉴。
Aiming at the fault of no data displayed in the monitoring interface of CAWS600 automatic weather station,this paper analyzes the cause of failure from the aspects of acquisition and monitoring software,power system and communication system etc.And the relevant eliminating methods,the testing procedures and solutions are put forward,which would provide references to other stations.