摘要
解读了国际海上人命安全公约中关于客船及货船消防泵、应急消防泵分舱布置和防火要求的规定。船舶消防泵分舱布置的不同会决定是否配置应急消防泵,当设置应急消防泵后,消防泵和应急消防泵所在舱室的共用舱壁防火要达到控制室的结构防火标准。介绍了2艘实船的消防泵分舱布置及防火要求。在实际工作中,需要多个专业协调,以确保消防泵和应急消防泵的分舱布置和防火要求符合海上人命安全公约的要求。
The requirements in International Convention for Safety of Life at Sea concerning the subdivision layout and fire protection of fire pumps and emergency fire pumps on passenger ships and cargo ships are interpreted. Because of fire pumps' different subdivision layout, it will be decided whether or not to deploy emergency fire pumps. When the emergency fire pumps are installed, the fire protection of the common bulkhead of the cabin where the fire pumps and the emergency fire pumps are located must meet the fire protection standards of the control room. Subdivision layout and fire protection requirements of fire pumps on two real ships are introduced. Multi-professional coordination is required in practice to ensure that the subdivision layout and fire protection requirements on fire pumps and emergency fire pumps comply with the requirements of the SOLAS.
作者
姚锋
李恒伟
YAO Feng;LI Hengwei(Shanghai Zhenhua Heavry Industries Co.,Ltd.,Shanghai 200125,China)
出处
《机电设备》
2018年第3期43-46,共4页
Mechanical and Electrical Equipment
关键词
船舶
消防泵
应急消防泵
分舱
防火
ship
fire pump
emergency fire pump
subdivision layout
fire protection