当前,被动式低能耗建筑得到了较快发展,所需围护结构的部品及施工技术不断获得突破并日臻完美,被动式低能耗建筑已从试验阶段向全面推广阶段快速迈进。在构成被动式低能耗建筑三大围护部品中,被动式低能耗建筑用门(以下简称"被动门")不同于外窗和墙体保温材料,由于受国家建筑安防、技防和消防标准的限制,对"被动门"的选择有着严格的要求。本文依据国家有关建筑、消防标准浅议如何正确选择"被动门",并得出"被动门"的定义。
At present, passive and low energy consumption buildings have been developed rapidly. Besides, the envelop products and construction technology are constantly broken through and getting perfect. Passive low energy consumption buildings have been rapidly advanced from the experimental stage to the comprehensive promotion. Among the three major envelope products of passive and low energy consumption buildings, the door of passive and low energy consumption buildings(hereinafter referred to as "passive door") is different from the exterior window and insulating wall material. The choice of the "passive door" is strictly restricted because of the national standards for security, technical defense and fire protection. Based on the national standards of buildings and fire protection, a brief discussion on how to choose the right passive door is presented and the definition of passive door is drawn in this paper.