摘要 常压塔结盐严重影响常压塔操作,会造成塔顶温度大幅波动、塔顶温度控制反应迟钝和产品质量不合格,且结盐部位会发生严重腐蚀。以某厂为例,对常压塔结盐的原因进行探讨,提出防范措施,并对常压塔水洗过程中的防腐蚀工作及监控进行分析研究。 Salt deposit in atmospheric tower can seriously affect tower operation,which may result in unstable temperature,insensitivity of temperature reaction,unqualified product and serious corrosion in salt deposit part. Take a refinery for an example,reasons for salt deposition were discussed and preventive measures were put forward. Anticorrosion measures and monitoring in water washing process were analyzed and studied.
作者 朱永平 张振强 韩磊 ZHU Yongping;ZHANG Zhenqiang;HAN Lei(SINOPEC Qingdao Refining & Chemical Co.,Ltd.,Qingdao 266500,China;SINOPEC Qingdao Safety Engineering Institute,Qingdao 266071,China)
出处 《石油化工腐蚀与防护》 CAS 2018年第2期41-43,共3页 Corrosion & Protection In Petrochemical Industry
基金 中国石油化工股份有限公司炼油事业部课题"常减压装置低温腐蚀预测模型与工艺防腐指导研究"(CLY17075)
关键词 常压塔 结盐 水洗 腐蚀监测 atmospheric tower salt deposit water washing corrosion monitoring