级联式电能质量发生装置整流侧控制策略研究 被引量:1

Research on Rectifier Side Control Strategy of Cascade Power Quality Generator
下载PDF
导出
摘要 H桥级联是高压大容量电能质量发生装置的典型拓扑,每相由多个背靠背整流逆变器串联而成,直流电压的状态直接决定整个装置的性能。由于装置需要向电网回馈能量,输出电压自身带有电能质量问题,因此与其他变流装置相比,整流逆变器直流电压的稳定控制难度更大。在此采用功率解耦控制联合比例积分(PI)控制方法,在稳定直流电压的同时确保输入功率因数为1。仿真和实验结果表明,该方法对四象限运行的整流逆变电路的直流电压波动有较好的抑制效果,使得电能质量发生装置具有良好的整体性能。 H-bridge cascade is the typical topology of high-voltage and large-capacity power quality generator, each phase is consist of many back-to-back converters, the performance of device is determined by the state of direct current voltage.Because generator need to feedback the electrical energy to grid and output voltage is accompanied by power quality.Direct current voltage stability control of the converter is more difficult than other converter devices.The method of power decouple combined with proportional integral(PI) control is adopted to stable direct current voltage andthe input power factor is ensured to be 1 at the same time.Simulation and experimental results show that this method had good restrain effect on direct current voltage fluctuation of four-quadrant converter, and made sure power quality generator equipped with good performance.
作者 李文锋 訾振宁 曾辉 张健 LI Wen-feng;ZI Zhen-ning;ZENG Hui;ZHANG Jian(China Electric Power Research Institute,Beijing 100192,China)
出处 《电力电子技术》 CSCD 北大核心 2018年第8期98-100,共3页 Power Electronics
基金 国家重点研发展计划(2016YFB0900605) 国家电网公司科技项目(XT71-16-029)~~
关键词 控制 电能质量 级联 control power quality cascade
  • 相关文献

参考文献4

二级参考文献34

  • 1韩民晓,金秀月,尤勇,潘丽珠.VSI型电力扰动发生装置的实现[J].电工技术杂志,2004,26(10):65-67. 被引量:11
  • 2赵剑锋,王浔,潘诗锋.基于双脉宽调制变换器和电压滞环控制的电能质量信号发生装置[J].电网技术,2005,29(4):41-44. 被引量:10
  • 3赵剑锋,王浔,潘诗锋.大功率电能质量信号发生装置设计及实验研究[J].电力系统自动化,2005,29(20):71-75. 被引量:18
  • 4陈伯时.电力拖动自动控制系统[M].第3版.北京:机械工业出版社,2003.
  • 5Jewell W. Power quality laboratory testing[C]. IEEE Power Engineering Review, Kansas, USA, 2002.
  • 6山本和生.瞬时电压低下发生实验装置.关西电力,2000,(7):39-39.
  • 7Girgis A A, Makrarn E B, Baldwin T L. Computer-based harmonic generator facilities to study harmonic related problems[J]. IEEE Trans on PowerSystems, 1989, 4(3): 1252-1257.
  • 8Nho E C, Kim L D, Park S D, et al. Reduced voltage drop characteristics of the series transformer in a voltage disturbance generator[C]. The 7th International Conference on Power Electronics, Daegu, Korea, 2007.
  • 9Lee Y H, Park H Y, Nho E C, et al. Improved voltage disturbance generator for the performance test of the custom power devices[C]. International Conference on Electrical Machine and Systems, Seoul, Korea, 2007.
  • 10Nho E C, Lee Y H, Jung J H, et al. Load independent voltage drop characteristics of a voltage disturbance generator with nonlinear load[C]. International Power Electronics and Motion Control Conference, Wuhan, China, 2009.

共引文献21

同被引文献21

引证文献1

二级引证文献13

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部