为了防止人员触电伤亡事故和漏电引起火灾导致播出事故,在我台的供电系统中安装使用漏电断路器来保证我台播出系统供电安全性。从漏电断路器的原理和作用入手,以电工原理为依据,分析因接线错误引起漏电断路器误动作的故障情况,并从实际工作出发提出相应的解决措施和方法,以提高我台供电稳定性和可靠性,确保安全播出供电。
The fault conditions of the breaker mulfunction caused by wiring mistakes are andyzed in the paper and propose solving measures and methods auording to practice work,improving our station’s power supply stability and reliability in order to supply power in safety.