选取溧阳台、南通台和盐城台等6个台站作为研究样本,对江苏地区CMG-3TB地震计使用过程中的故障情况进行整理,对故障原因进行分析,同时针对故障原因提出建议,旨在为提高井下地震计观测的可靠性提供参考。
6 seismological the fault conditions during fault causes and proposes ground seismometers. stations, which include Liyang, Nantong and Yancheng, are selected in order to sort out operation of the CMG-3TB seismometers in Jiangsu province. This paper analyzes the suggestions intended to provide reference for improving the operation reliability of underground seismometers.
作者
胡米东
毛华锋
陈启林
王皓
霍雨佳
黄群
张杰
HU Midong;MAO Huafeng;CHEN Qilin;WANG Hao;HUO Yujia HUANG Qun;ZHANG Jie(Liyang Seismological Station,Jiangsu Liyang 213332,China)
出处
《四川地震》
2018年第3期36-41,共6页
Earthquake Research in Sichuan
基金
中国地震局三结合课题