基于SOGI和级联DSC的正负序分量分离及其在不平衡PWM整流器中的应用 被引量:5

Separation of Positive and Negative Sequence Component Based on SOGI and Cascade DSC and Its Application in Unbalanced PWM Rectifier
下载PDF
导出
摘要 二阶广义积分器(SOGI)和级联延迟信号消除(DSC)都可用于正负序分量分离,但都有各自的缺点。为了从不平衡电网中提取电网的正序和负序基波分量,提出了消除高次谐波的SOGI和消除特定频率的DSC消谐策略。仿真结果表明,无论是在电网电压失真,还是发生对称故障和不对称故障的情况下,该方法都可以快速、准确地分离电网的正负序基波分量,并且还可用于不平衡脉冲宽度调制整流器的控制。 The second-order generalized integrator(SOGI) and cascade delayed signal cancellation(DSC) are used respectively in the separation of positive and negative component. But they have their own disadvantages. In order to extract grid's positive and negative sequence fundamental component from unbalanced power system,the strategy of second-order generalized integrator eliminating higher harmonic and cascade delayed signal cancellation eliminating the specific frequency harmonic is put forward. The simulation results showthat it can separate the positive and negative sequence fundamental components quickly and accurately in the case of grid voltage distortion,symmetrical fault and asymmetric fault,and it can be applied to the control of unbalanced pulse width modulation rectifier.
作者 吴军 程尹曼 程启明 薛阳 孙伟莎 WU Jun;CHENG Yinman;CHENG Qiming;X U EYang;SUN Weisha(Jiangsu Wuxi Guangying Electric Power Design Co.,Ltd.,Wuxi 214171,China;North Power Supply Branch of Shanghai Electric Power Company,Shanghai 200041,China;Shanghai University of Electric Power,Shanghai 200090,China)
出处 《上海电力学院学报》 CAS 2018年第4期356-360,共5页 Journal of Shanghai University of Electric Power
基金 国家自然科学基金(61573239) 上海市自然科学基金(15ZR1418600)
关键词 级联延迟信号消除 二阶广义积分 正负序分量 不平衡脉冲宽度调制整流器 cascade delayed signal cancellation second-order generalized integrator positiveand negative component unbalanced pulse width modudation rectifier
  • 相关文献

参考文献8

二级参考文献90

  • 1吴忠强,王子洋,邬伟扬.基于模糊自整定PI控制和重复控制的单相正弦脉宽调制逆变电源复合控制方案[J].电网技术,2005,29(14):30-34. 被引量:19
  • 2徐健飞,庞浩,王赞基,陈建业.新型全数字锁相环的逻辑电路设计[J].电网技术,2006,30(13):81-84. 被引量:21
  • 3孔雪娟,罗昉,彭力,康勇.基于周期控制的逆变器全数字锁相环的实现和参数设计[J].中国电机工程学报,2007,27(1):60-64. 被引量:45
  • 4IRAVANI M R,KARIMI-GHARTEMANI M. Online estimation of steady state and instantaneous symmetrical components[J]. IEE Proceedings-Generation,Transmission and Distribution,2003, 150(5) :616-622.
  • 5GI-IOSH A,JOSHI A. A new approach to load balancing and power factor correction in power distribution system[J]. IEEE Transactions on Power Delivery, 2000,15 ( 1 ) : 417-421.
  • 6PAAP G C. Symmetrical components in the time domain and their application to power network calculations[J]. IEEE Transactions on Power Systems, 2000,15 (2) : 522-528.
  • 7HSU J S. Instantaneous phasor method for obtaining instantabalanced fundamental components for power quality control and continuous diagnostics[J]. IEEE Transactions on Power Delivery, 1998,13(4) : 1494-1500.
  • 8YUAN X,MERK W,STEMMLER H,et al. Stationary-frame generalized integrators for current control of active power filters with zero steady-state error for current harmonics of concern under unbalanced and distorted operating conditions[J]. IEEE Transactions on Industry Applications, 2002,38 (2) : 523-532.
  • 9CIOBOTARU M,TEODORESCU R,BLAABJERG F. A new single-phase PLL structure based on second order generalized integrator[C]//Proceedings of Power Electronics Specialists Conference. Jeju, Korea : IEEE, 2006 : 1-6.
  • 10GAO Mingzhi,LI Baohong,CHEN Min,et al. Analysis and implementation of a PLL structure for single-phase grid-connected inverter system[C]//Proceedings of Power Electronics and Motion Control Conference. Wuhan, China : IEEE, 2009 : 716-719.

共引文献184

同被引文献36

引证文献5

二级引证文献9

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部