地铁作为城市交通重要的一个分支,近年来越来越广泛的在各大城市兴建,同时地铁防水质量问题也越来越突出,就车站漏水的原因做了简要分析,并针对外包防水层及结构自身防水两个重要环节的施工要点做了阐述,旨在提高地铁车站的防水质量,确保施工中、竣工后,使用年限内都不出现渗漏现象,为地铁车站的顺利运营提供安全保障。
The subway, as an importance branch of city transportation, is widely built in various cities. Meanwhile, subway waterproofing quality problem becomes more and more urgent. The paper analyzes the subway station leakage causes, and describes the construction points of outer waterproofing layer and structural waterproof, with a view- to improve the subway station waterproofing quality, to guarantee the leakage resistance during and after construction completion, and to insure the smooth and safety subway station operation as well.
作者
赖俊池
Lai Junchi(China Railway City Development Investment Group Co.,Ltd,Chengdu 610000,China)
出处
《山西建筑》
2018年第23期215-217,共3页
Shanxi Architecture
关键词
地铁车站
防水施工技术
质量控制
subway station
waterproof construction technology
qualiy control