期刊文献+

城轨交流牵引供电系统接触网标称电压探讨 被引量:2

Discussion on OCS Nominal Voltage of AC Traction Power Supply System of Urban Rail Transit
下载PDF
导出
摘要 介绍城轨交流牵引供电系统的研究现状及设计条件,确定接触网标称电压的论证范围。从牵引供电系统电压损失计算方法适用性、接触网组成、钢轨电位、牵引网电压水平和最长供电距离5个方面对不同标称电压进行分析和对比,得出城轨交流牵引供电系统接触网标称电压宜选择6.0 k V。 Introduces the current status of researches and conditions of design for AC traction power supply system of urban rail transit, defines the theoretical scope of OCS nominal voltage. Analysis and comparisons are made for various nominal voltages in terms of 5 aspects of applicability of calculation methods of voltage loss of traction power supply system, composition of OCS, rail potential, traction network voltage level and maximum power supply distance, and the conclusion is obtained that 6.0 k V should be selected for the OCS nominal voltage.
作者 刘政 张丽艳
出处 《电气化铁道》 2018年第4期40-43,共4页 Electric Railway
关键词 城轨交流牵引供电系统 标称电压 牵引网电压水平 最长供电距离 AC traction power supply system of urban rail transit nominal voltage traction network voltage level maximum power supply distance
  • 相关文献

参考文献5

二级参考文献40

  • 1汤向华.110kV及以下电网合环保护调整[J].农村电气化,2006(9):28-30. 被引量:3
  • 2冯慈章.电磁场[M].北京:高等教育出版社,1983.160.
  • 3TB10009-2005铁路电力牵引供电设计规范[S].中华人民共和国铁道部,2005.
  • 4全国电压电流等级和频率标准化委员会.电压电流频率和电能质量国家标准应用手册[M].北京:中国电力出版社,2001.
  • 5[1]Carson J R.Wave propagation in overhead wires with ground return[J].Bell System Technical Journal,1996,(5):539-554.
  • 6[3]Tylavsky D J,Brown K A,Ma T T.Closed-form solution for underground impedance calculations[J].proceedinds of the IEEE,1986,74(9):1290-1292.
  • 7[4]Tylavsky D J.Conductor impedance approximations for deep-underground mines[J].IEEE Trans.on Industry Applications,1987,IA-23(4):723-730.
  • 8曹建猷.电气化铁道供电系统[M].北京:中国铁道出版社,1984.71—200.
  • 9中国国家标准化管理委员会.GB/T15543-2008电能质量三相电压不平衡[S].北京:中国标准出版社,2008.
  • 10李群湛,张进思,贺威俊.适于重载电力牵引的新型供电系统的研究[J].铁道学报,1988,10(4):23.31.

共引文献258

同被引文献7

引证文献2

二级引证文献3

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;