期刊文献+

基于热空气老化法的橡胶减振器寿命评估 被引量:3

Life Prediction of Rubber Shock Absorber Based on Hot Air Aging Test Method
下载PDF
导出
摘要 本文基于热空气老化试验方法,选取某种航空用橡胶减振器常温状态下减振率衰减率为关键考核指标,研究该指标随着温度及老化时间的关系,建立其寿命推算公式,预测该减振器常温使用寿命为20年,满足设计要求,为该产品的设计和使用提供相关依据。 Based on hot air aging test method, this paper selects attenuation rate of a certain rubber shock absorber for aviation under the condition of room temperature as the key assessment indicators and studies the relationship of the index with temperature and aging time, to establish its life estimation formula. It is predicted that the shock absorber at room temperature will serve for 20 years, and can meet the design requirements, which provides relevant basis for the design and use of product.
作者 李丽远 杨飞虎 刘军 王和 陈国一 LI Li-yuan;YANG Fei-hu;LIU Jun;WANG He;CHEN Guo-yi(Tianjin Aerospace Reliability Technology Co.,Ltd.,Shenyang 110000;Beijing Institute of Structure and Environment Engineering,Beijing 100076)
出处 《环境技术》 2018年第4期71-74,共4页 Environmental Technology
关键词 减振器 橡胶 老化试验 寿命预测 shock absorber rubber aging test life prediction
  • 相关文献

参考文献5

二级参考文献34

  • 1李咏今.氯丁橡胶胶老化性能变化与老化温度和时间之间关系的研究[J].橡胶工业,1993,40(2):103-106. 被引量:8
  • 2王铁军.舰船电缆热老化寿命的研究[J].海军工程大学学报,2000,12(1):76-79. 被引量:18
  • 3熊渲.硅橡胶密封材料贮存寿命的预测[J].宇航材料工艺,1996,26(2):83-87. 被引量:11
  • 4石拓,金荣福,石柘.论高分子材料的加速老化[J].高分子材料科学与工程,1990,6(5):9-12. 被引量:6
  • 5Wise J, Gillen K T.An ultrasensitive technique for testing Arrhenius extrapolation assumption for thermally aged elastomers [J].Polymer Degradation and Stability,1995,49:403-418.
  • 6Forost N E, Xu G.An examination of the environment for aging of polymer[A].1997 IEE Annual Report--Conference on Electrical Insulation and Dielectric Phenomena,Minneapolis:Oct.19-22,1997. 354-357.
  • 7Koo J Y, Kim I T.An experiment investigation on the de-gradation characteristic of the outdoor silicone rubber due to sulfate and nitrate ions[A].1997 IEE Annual Report--Conference on Electrical Insulation and Dielectric Phenomena,Minneapolis:Oct.19-22,1997. 370-373.
  • 8Gillen K T, Clough R L.DOE-Sponsored cable aging research at sandia national laboratories [R].Albuquerque: Sandia National Laboratories,1997.
  • 9Gillen K T, Wise J.Evidence Arrhenius high-temperature a-ging behavior for an EPDM O-ring does not extroplate to lo-wer temperature [R].Albuquerque: Sandia National Laboratories,1997.
  • 10Gillen K T.New method for predicting lifetime of seals from compression-stress relaxation experiments[R].Albuquerque: Sandia National Laboratories,1998.