期刊文献+

3D SPCACE STIR序列在腰骶部肿瘤性病变应用研究 被引量:2

Application of 3D SPCACE STIR sequence in lumbosacral tumor lesions
下载PDF
导出
摘要 目的探讨3D SPACE STIR序列在腰骶部肿瘤性病变的诊断价值。方法收集2008年8月~2016年12月腰骶部肿瘤性病变行常规MR序列和3D SPACE STIR序列检查,将检查结果与手术结果进行对照分析。结果 46例进行3D SPCACE STIR序列肿瘤性病变,神经源性肿瘤16例,转移性肿瘤12例,畸胎瘤5例,淋巴瘤3例,恶性纤维组织细胞瘤3例,多发骨髓瘤4例,软骨肉瘤3例。3D SPACE STIR序列能显示大部分神经源性肿瘤相关的起源神经。结论3D SPCACE STIR序列能够立体清晰显示腰骶部肿瘤性病变的范围,形态及与周围结构的关系。 Objective To investigate the diagnostic value of 3 D SPACE STIR sequence in lumbosacral tumor lesions. Methods From August 2008 to December 2016,we collected a series of cases of cancer of the 3 D SPACE STIR sequence,the results were compared with the results of surgery. Results There were 46 cases of 3 D SPCACESTIR sequence neoplastic lesions and 16 cases of neurogenic tumor,metastatic tumor in 12 cases,5 case of teratoma,and 3 case of lymphoma,malignant fibrous histiocytoma in 3 case,4 case of multiple myeloma,and 3 chondrosarcoma. 3 D SPCACE STIR sequence can show the origin of most neurogenic tumors. Conclusion The 3 D SPACE STIR can clearly show the range of lumbosacral tumor lesions,morphology and the relationship with the surrounding structure.
作者 黄莹 肖文丰 HUANG Ying;Xiao Wenfeng(Oncdogy Department Shengli Central Hospital,Dongying 257034,P.R.China;MR Department Shengli Central Hospital Dongying 257034,P.R.China)
出处 《医学影像学杂志》 2018年第8期1349-1351,1366,共4页 Journal of Medical Imaging
关键词 磁共振成像 肿瘤性病变 Magnet resonance imaging Neoplastic lesions
  • 相关文献

参考文献6

二级参考文献39

  • 1林江凯,叶信珍,夏永智,冯华,朱刚,王宪荣.症状性Tarlov囊肿的发病机制与显微手术治疗(附20例分析)[J].中国微侵袭神经外科杂志,2008,13(9):406-408. 被引量:6
  • 2姚秋英,许建荣,李磊.三维动态对比增强磁共振血管成像在门静脉系统成像中的应用价值[J].中国医学影像技术,2005,21(10):1531-1533. 被引量:3
  • 3无,李建军(译),周红俊(译),孙迎春(译),张新(译),王方永(译),高峰(译),周天健(译).脊髓损伤神经学分类国际标准(第6版,2006)[J].中国康复理论与实践,2007,13(1):1-6. 被引量:111
  • 4舒仁义,张霞萍,叶孟.16例神经根囊肿的影像学诊断[J].临床医学,2007,27(1):19-22. 被引量:6
  • 5Fautz HP,Leupold J,Hennig J,et al.Signal behavior in continuously ramped 2D TrueFISP for whole-body imaging.Magn Reson Med,2002,48(6):1085-1090.
  • 6Lichy MP,Wietek BM,JP Mugler 3rd,et al.Magnetic resonance imaging of the body trunk using a single-slab,3-dimensional,T2-weighted turbo-spin-echo sequence with high sampling efficiency (space) for high spatial resolution imaging:initial clinical experiences.Invest Radiol,2005,40(12):754-760.
  • 7Mugler JP.Variable-flip-angle strategies for T2-weighted 2D TSE:a preliminary theoretical comparison.Siemens Medical Solutions Erlangen,2002.
  • 8Hennig J,Scheffler K.Hyperechoes.Magn Reson Med,2001,46(1):6-12.
  • 9Mugler JP,Brookeman JR.Ultra-long echo trains for rapid 3D T2-weighted turbo-spin-echo imaging.Proc ISMRM,2003,11:970.
  • 10Mugler JP,Meyer H,Kiefer B.Practical implementation of optimized tissue-specific prescribed signal evolutions for improved turbo-spin-echo imaging.Proc ISMRM,2003,11:203.

共引文献48

同被引文献16

引证文献2

二级引证文献12

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部