迭代重建算法在儿童CT中应用新进展 被引量:6

The application and progress of iterative reconstruction in children CT
下载PDF
导出
摘要 用低剂量扫描方案进行儿童CT检查已经成为共识,近年来低剂量扫描方案的研究热点集中在迭代重建算法(iterative reconstruction,IR)的应用上,随着IR在儿童CT检查的应用普及,充分了解IR在儿童CT上的应用特点变得愈发重要,因此,本文对IR在儿童CT检查中的应用现状、优缺点、进展工作做一综述报道。 The use of low dose scanning protocol for children CT has become a consensus. In recent years,iterative reconstruction(IR) is a key technique and research focus in the low dose CT. As the development of IR,fully understanding of IR and application in children is becoming more and more important. So,the present situation of application,advantage,disadvantage and the progress for the usage of IR in children CT are reviewed
作者 孙记航 彭芸 SUJV Jihang;PENG Yun(Department of Radiology,Beifing Children's Hospital,Capital Medical University,National Center for Children's Health,Beijing 100045,P.R.China)
出处 《医学影像学杂志》 2018年第8期1387-1389,共3页 Journal of Medical Imaging
关键词 儿童 迭代重建 体层摄影术 X线计算机 Children herative reconstruction Tomography X-ray computed
  • 相关文献

参考文献4

二级参考文献77

  • 1Colang JE, Killion JB, Vano E. Patient dose from CT: a literature review. Radiol Technol,2007,79 : 17-26.
  • 2Brenner D J, Hall EJ. Computed tomography:an increasing source of radiation exposure. N Engl J Med,2007 ,357 :2277-2284.
  • 3Brody AS, Frush DP, Huda W, et al. Radiation risk to children from computed tomography. Pediatrics ,2007,120:677-682.
  • 4Campbell J, Kalra MK, Rizzo S, et al. Scanning beyond anatomic limits of the thorax in chest CT: findings, radiation dose, and automatic tube current modulation. AJR,2005,185 : 1525-1530.
  • 5Donnelly LF, Emery KH, Brody AS,et al. Minimizing radiation dose for pediatric body application of single-detector helical CT: strategies at a large Children's Hospital. AJR, 2001, 176: 303 -306.
  • 6Nyman U, Ahl TL, Kristiansson M, et al. Patient-circumference- adapted dose regulation in body computed tomography, a practical and flexible formula. Acta Radiol, 2005,46:396-406.
  • 7Sigal-Clinquabre AB, Hennequin R, Abada HT, et al. Low- kilovohage multi-detector row chest CT in adults: feasibility and effect on image quality and iodine dose. Rdiology,2004,231: 169-174.
  • 8Thomas CK, Muhlenbruch G, Wildberger JE, et al. Coronary artery calcium scoring with muhislice computed tomography: in vitro assessment of a low tube voltage protocol. Invest Radiol, 2006, 41:668-673.
  • 9Heneghan JP, McGuire KA, Leder RA, et al. Helical CT for nephrolithiasis and ureterolithiasis: comparison of conventional and reduced radiation : dose techniques. Radiology, 2003,229 :575-580.
  • 10Haaga JR, Miraldi F, Maclntyre W, et al. The effect of mAs variation upon computed tomography image quality as evaluated by in vivo and in vitro studies. Radiology, 1981, 138:449-454.

共引文献104

同被引文献32

引证文献6

二级引证文献12

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部