摘要
根据国家标准规定和国家核安全局要求,核电厂需定期申请流出物排放量。本文论述了多属性分析方法在方家山核电项目液态流出物排放量优化研究中的应用。对废液处理系统(TEU)流出物排放所致关键居民组的个人剂量、集体剂量、工作人员剂量、废物处理所需费用、固体废物对后代的影响等五个因素进行综合分析,确定了方家山核电工程液态流出物的优化排放量。
According to the requirements of national regulations and National Nuclear Safety Agency,radioactive effluent release amount should be approved regularly. Multi-attribute analysis theory and its application in the optimization of the effluent release amount of Fang Jiashan nuclear power project is described. Through comprehensive analysis on individual dose, collective effective dose, worker dose from TEU system and radioactive waste disposal cost and descendant effect,the optimized amount of liquid effluent release of Fang Jiashan nuclear power project is given.
作者
张晶
翟良
朱月龙
ZHANG Jing;ZHAI Liang;ZHU Yuelong(CNNC Nuclear Power Operations Management Co.Ltd.,Zhejiang Haiyan 314300;Suzhou Nuelear Power Research Institute Co.Ltd.,Jiangsu Suzhou 215004)
出处
《辐射防护》
CAS
CSCD
北大核心
2018年第4期319-325,共7页
Radiation Protection
关键词
多属性分析
核电厂
液态流出物
排放量
优化
multi-attribute analysis
nuclear power plant
liquid effluent
release amount
optimization