期刊文献+

ICP-OES法测定铝合金中铬含量分析 被引量:1

Determination of Chromium Content in Aluminum Alloy by ICP-OES
原文传递
导出
摘要 本文旨在通过电感耦合等离子体发射光谱法研究测定铝合金中的铬元素的方法,对比分析铝基体溶液对实验结果的影响,得出最合适的实验方法。同时分析该实验方法的准确度和精密度,并从测量重复性、称样过程、溶液定容过程、铬标准溶液本身及标准曲线五个方面考虑了该方法的不确定度,对今后的实验的结果有一定的指导意义。 This paper aims to study the method of determining chromium in aluminum alloy by inductively coupled plasma emission spectroscopy, compare and analyze the influence of aluminum matrix solution on experimental results, and obtain the most suitable experimental method. At the same time, the accuracy and precision of the experimental method are analyzed, and the uncertainty of the method is considered from five aspects: measurement repeatability, sample weighing process, solution volumetric process, certain guiding significance for chromium standard solution itself and standard curve, which has the results of future experiments.
作者 原秀芳 李巍 张亚威 高丽丽 葛之萌 YUAN Xiufang;LI Wei;ZHANG Yawei;GAO Lili;GE Zhimeng(Beijing Building Materials Testing Academy Co.,Ltd.,Beijing,100041,China)
出处 《金属材料与冶金工程》 CAS 2018年第4期59-63,共5页 Metal Materials and Metallurgy Engineering
关键词 电感耦合等离子体发射光谱仪 铝基体溶液 不确定度 铬元素含量 inductively coupled plasma emission spectrometer aluminum matrix solution uncertainty chromium content