针对几起电容式电压互感器(CVT)油箱发热缺陷,通过分析CVT油箱的内部结构、中间变压器的工作特性与原理,并结合现场特征,查找油箱发热具体原因。针对此类缺陷提出改进措施及建议,以杜绝此类缺陷的再次发生,保证电网的安全运行。
In view of the defect of fuel tank heating in capacitor voltage transformer(CVT),the internal structure of the CVT fuel tank,the operational characteristics and principles of intermediate transformer are analyzed,combined with the on-site characteristics,the specific reasons for the heating of fuel tank are found out.The improvement measures and suggestions are put forward to prevent the recurrence of such defect and ensure the safe operation of the power grid.
作者
麻震烁
陈东明
陈习文
高全
李旸
MA Zhenshuo;CHEN Dongming;CHEN Xiwen;GAO Quan;LI Yang(State Grid Jibei Electric Power Co.,Ltd.,Maintenance Branch,Beijing 102488,China)
出处
《电工技术》
2018年第13期92-93,96,共3页
Electric Engineering
关键词
电容式电压互感器
中间变压器
谐振
油箱
发热
capacitor voltage transformer
intermediate transformer
resonance
fuel tank
heating