摘要
结合天津商业项目的工程案例,从冷却塔免费供冷系统的设计和运行管理两方面进行了分析;对过渡季和冬季采取不同的运行方式进行了经济性比较。
This paper is combined with a commercial building in Tianjin.Two aspects are summarized and analyzed from the design and operation management of free-cooling system by cooling tower. The economic comparison of the different operating modes between the transition season and the winter is carried out.
出处
《建筑技术开发》
2018年第16期7-7,共1页
Building Technology Development
关键词
冷却塔免费供冷
冷却塔出水温度
冷却塔防冻
free-cooling by cooling tower
exit temperature of cooling water
antifreeze measures of cooling tower