期刊文献+

某9FA.03机组低压进汽控制阀异常现象分析处理 被引量:1

Analysis and Handling of Abnormal Phenomenon of Admission Control Valve of a 9FA.03 Unit
下载PDF
导出
摘要 介绍了某台9FA.03联合循环机组启动过程中汽轮机低压进汽控制阀(ACV)多次出现开启过程卡涩的现象。通过分析该异常现象,找到故障原因为阀门本体卡涩。并且提出了开启低压旁路调节阀,以降低ACV前压力的处理方法,提高了机组的安全性。研究成果可为同类型机组ACV卡涩现象的处理提供参考。 The jam phenomenon, which appeared many times in LP admission control valve (ACV) of steam turbine during start up of a 9FA. 03 combined cycle unit, is presented. Based on the analysis of the abnormal phenomenon, the fault reason is found out to be the jam of the valve body. Then, the method to reduce ACV pre pressure by opening the LP bypass regulating valve is presented to enhance the safety of the unit. The research findings can provide reference for handlfng the ACV jam fault of the units with the same type.
作者 张龚 ZHANG Gong(Jinjiang Natural Gas Power Generation Co.,Ltd.,Jinjiang 362251,China)
出处 《热力透平》 2018年第3期229-231,235,共4页 Thermal Turbine
关键词 燃气轮机 ACV 卡涩现象 gas turbine admission control valve jam phenomenon
  • 相关文献

参考文献1

共引文献1

同被引文献3

引证文献1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部