期刊文献+

直流电场中不同凝并参数对粉尘粒度分布的影响 被引量:1

Influence of Different Agglomerating Parameters on Dust Particle Size Distribution in DC Electric Field
下载PDF
导出
摘要 以预荷电室和凝并室为实验系统,对电凝并装置的凝并效果进行了研究,分析了凝并室直流电场中不同极配形式、不同峰值电压、不同烟道风速以及不同粉尘初始浓度对粉尘粒度分布的影响。研究结果表明,当粉尘初始质量浓度为1 g/m3、烟道风速为1.4 m/s、凝并室直流电压为30 k V、凝并室极配形式为双芒刺板时,可吸入颗粒物的凝并效果较好。 Based on the experimental system of precharge chamber and agglomeration chamber, the agglomeration effect of electric agglomeration unit was studied. T he influence of different polar matching forms and peak voltages in DC electric field of the agglomeration chamber, different flue wind velocity as well as initial particle concentration on the agglomeration effect of inhalable particle was analyzed. The results showed that when the initial particle concentration was 1 g/m3, the flue wind velocity was 1.4 m/s, the DC voltage was 30 k V and the polar matching form of agglomeration chamber was bipolar barbed plate, there was a good agglomeration effect of inhalable particles.
作者 黄超 蒋海岩 杨振民 马秀琴 孙兆玮 Huang Chao;Jiang Haiyan;Yang Zhenmin;Ma Xiuqin;Sun Zhaowei(Hebei University of Technology,Tianjin 300401,China)
机构地区 河北工业大学
出处 《煤化工》 CAS 2018年第4期69-72,共4页 Coal Chemical Industry
基金 河北省自然科学基金资助项目(E2018202333) 河北省科技计划项目(14273701D-1)
关键词 粉尘 电凝并 直流电场 可吸入颗粒物 荷电 烟道风速 极配形式 dust electric agglomeration DC electric field inhalable particle charge flue wind velocity polar matching form
  • 相关文献

参考文献6

二级参考文献149

共引文献230

同被引文献10

引证文献1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部