摘要
为了研究不同材质的金属对厌氧胶固化性能的影响,自制了一种厌氧胶,测试了该厌氧胶在铁、铜、304不锈钢、镀锌螺栓的定位时间和扭矩强度,结果表明:厌氧胶分别在铜、铁、304不锈钢、镀锌螺栓的定位时间为3min、8min、35min、37min,破坏扭矩分别为18.9N·m、28.8N·m、17.8N·m、20.2N·m,平均拆卸扭矩分别为29.4N·m、36.8N·m、24.5N·m、21.9N·m。本研究表明金属铜对厌氧胶固化速度的促进作用最大,铁次之,304不锈钢和镀锌最小;厌氧胶在铁螺栓上可获得最大的扭矩强度,铜次之,304不锈钢和镀锌最小。
In order to study the effect of different metal materials on the curing performance of anaerobic adhesive, an anaerobic adhesive was developed. The setting time and torque strength of the anaerobic adhesive in iron, copper, 304 stainless steel and galvanized bolts was tested, the results showed that the setting time of the anaerobic adhesive in copper, iron, 304 stainless steel and galvanized bolt were 3 min, 8 min, 35 min and37 min respectively; and the failure torque were 18.9 N·m, 28.8 N·m, 17.8 N·m and 20.2 N·m respectively; and the disassembly torque were 29.4 N·m,36.8 N·m, 24.5 N·m and 21.9 N·m respectively. This study showed that the promoting effect of metallic copper on the curing rate of anaerobic adhesive was the greatest, followed by the iron, 304 stainless steel and galvanization. The maximum torque strength of anaerobic adhesive was achieved on iron bolts, followed by on copper, and it was minimal on the 304 stainless steel and galvanized bolt.
作者
黄钊芬
覃燕龙
姚荣茂
彭小琴
关志涛
刘若泰
HUANG Zhao-fenl;QIN Yan-long;YAO Rong-mao;PENG Xiao-qin;GUAN Zhi-tao;LIU Ruo-tai(Guangdong Sanvo Holdings Ltd.,Zhongshan 528434,China;Guangdong Sanvo Chemical Technology Co.,Ltd.,Zhongshon 528434,China;Guangdong Fuvo Industrial Co.,Ltd.,Zhongshan 528434,China)
出处
《化学与粘合》
CAS
2018年第5期355-356,共2页
Chemistry and Adhesion
关键词
厌氧胶
金属
定位时间
扭矩强度
Anaerobic adhesive
metal
setting time
torque strength