期刊文献+

导电玻璃钢电除雾器的故障与维修 被引量:1

Failure and maintenance of conductive FRP electrostatic demister
下载PDF
导出
摘要 针对冶炼烟气制酸系统导电玻璃钢电除雾器的运行故障,从电除雾器本体及系统工艺参数进行了深入分析,对电除雾器的电接触、绝缘值及气流分布板进行了优化;为了减小电除雾器的负荷,在电除雾器前的填料塔增加了丝网除雾器并控制了填料塔循环稀酸的浓度。 Aiming at the operation failure of conductive FRP electrostatic demister in acid-making system of smelting flue gas,theelectrical contact,insulation value and gas distribution plate of the electrostatic demister were optimized through in-depth analysis of theelectrostatic demister body and system process parameters.In order to reduce the load of the electrostatic demister,a wire mesh demisterwas added into the packed tower in front of the electrostatic demister and the concentration of circulating dilute acid in the packed towerwas under control.
作者 张纪红 卫立楷 李立建 程文军 ZHANG Jihong;WEI Likai;LI Lijian;CHENG Wenjun(Henan Yuguang Zinc Industry Co.,Ltd.,Jiyuan,Henan,459000,China)
出处 《硫酸工业》 CAS 2018年第8期50-52,共3页 Sulphuric Acid Industry
关键词 导电玻璃钢电除雾器 分布板 绝缘值 填料塔 丝网除沫器 循环稀酸 conductive FRP electrostatic demister distribution plate insulation value packed tower wire mesh demister circulating dilute acid
  • 相关文献

参考文献2

二级参考文献1

共引文献8

同被引文献2

引证文献1

二级引证文献2

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部