双能量CT碘含量定量分析在肺实质血流灌注的初步研究 被引量:7

Preliminary Study on the Quantitative Analysis of Iodine with Dual Energy CT for Pulmonary Parenchymal Perfusion
下载PDF
导出
摘要 目的评价双能量CT碘含量对正常人肺实质首过血流灌注的定量价值。方法回顾性分析了心肺检查正常的15例患者的首过肺实质血流灌注图像,并进行碘含量的测定,对肺部不同区域的碘含量值进行统计学分析。结果同侧肺相同水平位置腹侧和背侧肺实质血流灌注碘含量值有显著的统计学差异,腹侧的血流灌注碘含量均值低于背侧;左右侧肺相同位置区域肺实质血流灌注碘含量值大部分有统计学差异,左肺的肺实质血流灌注碘含量均值高于右肺(P>0.05)。结论肺实质首过血流灌注的碘含量值可以敏感的反应肺实质不同区域的血流灌注差异。 Objective To evaluate the value for quantitative analysis of the iodine concentration in pulmonary parenchymal with dual-energy CT perfusion imaging. Methods 15 patients without cardiac and pulmonary abnormality were accepted the dual-energy CT scanning. The data was post-processed on Siemens workstation to obtain PBV images, the iodine concentrate were calculated, which of the different area in pulmonary parenchymal were analyzed. Results Mean of iodine content in the ventral was significantly lower than the ipsilateral dorsal lung at same horizontal position; Meanwhile, the mean of iodine content in the left was higher than the right lung at the same horizontal position, however there were no significant differences between the two regions(P〈0.05). Conclusion The iodine concentrate of PBV is sensitive to the perfusion difference of the pulmonary parenchymal with dual-energy CT perfusion imaging.
作者 王岳 高莉 张晓东 赵永为 刘建新 王霄英 WANG Yue;GAO Li;ZHANG Xiao-dong(Department of Medical Imaging,Peking University First Hospital,Beijing 100034,China)
出处 《中国CT和MRI杂志》 2018年第8期43-45,共3页 Chinese Journal of CT and MRI
关键词 肺灌注 碘含量 计算机体层成像 双能 Pulmonary Perfusion Iodine Content CT Dual Energy
  • 相关文献

参考文献3

二级参考文献24

  • 1张竹花,金征宇,张抒扬,林松柏,李冬晶,孔令燕,王怡宁,宋兰,王云,赵文敏,王林辉,张晓娜,张云庆,齐冰,徐凯,梁继祥,朱海峰,牟文斌,张立仁,朱文玲,苗齐,方圻.高心率患者双源CT冠状动脉成像初步研究[J].实用放射学杂志,2007,23(8):1106-1109. 被引量:22
  • 2Liu X, Yu L, Primak AN, et al. Quantitative imaging of element composition and mass fraction using dual-energy CT: three-mate- rial decomposition[J]. Med Phys,2009,36(5) :1602-1609.
  • 3Matsumoto K,Jinzaki M,Tanami Y.et al. Virtual monochromatic spectral imaging with fast kilovoltage switching: improved image quality as compared with that obtained with conventional 120kVp C'I'[J . Radiology, 2011,259 ( 1 ) : 257-262.
  • 4Catalano C, Francone M, Ascarelli A, et al. Optimizing radiation dose and image quality[J]. Eur RadioI, 2007,17 (Suppl 6): F26-32.
  • 5Gorgos A, Remy-Jardin M, Duhamel A, et al. Evaluation of peripheral pulmonary arteries at 80 kV and at 140 kV: dual-energy computed tomography assessment in 51 patients[J]. J Comput Assist Tomogr,2009,33(6) :981-986.
  • 6Paul J,Bauer R W,Maentele W,et al. Image fusion in dual ener- gy computed tomography for detection of various anatomic struc tures-effect on contrast enhancement, contrast-to-noise ratio, signal-to-noise ratio and image quality[J]. Eur J Radiol, 2011,80 (2) :612-619.
  • 7张龙江,卢光明,黄伟,蔡军,周长圣,赵艳娥,陈鹏.双源CT双能量肺灌注成像的初步观察[J].中华放射学杂志,2008,42(11):1183-1186. 被引量:51
  • 8张龙江,吴新生,赵艳娥,周长圣,柴学,黄伟,卢光明.双源CT双能量肺灌注成像在可疑肺栓塞患者的初步应用[J].临床放射学杂志,2009,28(4):474-478. 被引量:17
  • 9赵艳娥,张龙江,周长圣,胡小波,胡秋菊,顾海峰,潘永泉,曹新志,卢光明.双源CT双能量肺灌注成像诊断急性肺栓塞的实验研究[J].中华放射学杂志,2009,43(6):651-655. 被引量:31
  • 10B.M.Yeh,郭雪梅.双能CT肺栓塞检出的兔动物模型双源CT扫描的实验研究[J].国际医学放射学杂志,2009,32(5):484-484. 被引量:53

共引文献38

同被引文献79

引证文献7

二级引证文献24

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部