期刊文献+

大岗山水电站2F机组接力器自动锁锭发卡处理 被引量:1

Analysis and Treatment of the Automatic Lock Spindle Jam Fault of the Servomotor in No.2F Unit in Dagangshan Hydropower Station
下载PDF
导出
摘要 大岗山水电站2F机组自2016-06-01日转商业运行后,接力器多次发生锁锭发卡现象。通过对接力器的结构、工作原理进行深入分析发现,接力器多次自动锁锭发卡的原因不尽相同,可能是锁锭电磁阀发卡、锁锭座水平偏差、接力器压紧行程变化等原因。在故障检修中,应针对不同的故障原因,对症下药,方能药到病除。 Since the commercial operation of the No. 2 F unit in Dagangshan Hydropower Station,lock spindle jam faults of the servomotor are observed several times. A detailed analysis is carried out on the structure and working principles of the servomotor. It is found that these jam faults are caused by different reasons,such as the jam of the lock spindle electromagnetic valve,horizontal deviation of the lock spindle seat,and variation of the servomotor compression stroke.Thus,different treatment measures should be taken in the maintenance according to different causes to solve the problem completely.
作者 廖家富 LIAO Jiafu(China Guodian Dadu River Maintenance and Installation Co.,Ltd.,Leshan 614900,China)
出处 《水电与新能源》 2018年第9期57-59,共3页 Hydropower and New Energy
关键词 大岗山水电站 2F机组 接力器自动锁锭发卡 Dagangshan Hydropower Station No. 2F unit automatic lock spindle jam of servomotor
  • 相关文献

参考文献4

二级参考文献4

  • 1汤正义.水轮机调速器械检修[M]北京:中国电力出版社,2003.
  • 2王文斌.机械设计手册新版第1卷一北京:机械工业出版社.2004.
  • 3何焯.设备起重吊装工程便携手册[M].北京:机械工业出版社.2004.
  • 4杨杰.水轮机检修、故障处理、运行调试维护综合技术手册一北京:北京科大电子出版社,2005.