采用流动注射法快速准确测定海水中可溶性硅酸盐,该方法很好的解决了测定过程中海水盐度干扰的问题。在优化好的试验条件下,方法检出限为0.050mg/L,浓度在0.00~2.40 mg/L具有良好的线性关系(相关系数0.999 9)。实际海水样测定的RSD为0.060%~0.21%,加标回收率为84%~100%,检测频率为35样/h。此方法与普通分光光度法相比具有快速、省时、方便、基体干扰小,精密度和准确性好等优点,适合批量样品的测定。
The method of flow injection is used to accurately determine the soluble silicate in seawater,which is a good way to solve the problem of salinity disturbance in the measuring process. In well optimized experimental conditions,the method detection limit of 0. 050 mg/L,the concentration in 0. 00 - 2. 40 mg/L has a good linear relationship( correlation coefficient 0. 9999),the actual water samples to determine the RSD was 0. 060% - 0. 21%,standard addition recovery was 84% - 100%,the detection frequency of 35 sample/h. This method is compared with common spectrophotometric method is fast,efficient,convenient and matrix interference is small,the advantages of good precision and accuracy,suitable for the batch sample determination.
作者
鲍静姣
尤炬炬
郭远明
王姮
Bao Jingjiao;You Juju;Guo Yuanming;Wang Heng(Marine Fishery Institute of Zhejiang Province,Zhoushan 316021,China;Key Laboratory of Sustainable Utilization of Technology Research for Fishery Resource of Zhejiang Province,Zhoushan 316021,China)