期刊文献+

基于辐射和对流换热新型供暖末端的空气源热泵除霜性能试验研究 被引量:4

Experimental study on defrosting performance of air source heat pump with new type heating terminal based on radiation and convection heat transfer
下载PDF
导出
摘要 常规空气源热泵在低温环境中运行时普遍存在结霜和除霜现象,由于常规室内盘管储能不足,导致逆循环除霜效果不理想。同时,基于强制对流换热的常规空气源热泵常常会引起室内热分层现象和强烈的吹风感,导致人体热舒适性较差。为解决上述问题,本文结合辐射供暖具有较高热舒适性的优点,提出一种基于辐射和强制对流换热的新型供暖末端,搭建空气源热泵辐射和对流换热性能试验台,对其除霜性能进行试验研究。结果表明:除霜周期内,该系统压缩机功率平均值为429.5 W,除霜能效比为2.88,除霜能效比高于常规空气源热泵系统。 The frosting and defrosting generally exist for conventional air source heat pumps running in low-temperature environment.Due to the insufficient energy stored in a conventional indoor coil,the defrosting performance of the reverse cycle defrosting is not ideal.Meanwhile,the conventional air source heat pump based on forced convective heat transfer often causes indoor thermal stratification and strong blowing sensation,resulting in poor thermal comfort.In order to solve the problem,considering the advantages of a radiant heating system with higher thermal comfort,a new type of heating terminal is presented based on radiation and forced convection heat transfer.In addition,the experimental platform of the radiation and forced convection heat transfer performance of air source heat pump is set up,and the defrosting performance of system is experimentally analyzed.The results show that during defrosting period,the average power of the compressor is 429.5 W,the defrosting energy efficiency ratio is 2.88,which is higher than that of the conventional air source heat pump system.
作者 董建锴 闫森 顾冬明 黄顺 Dong Jiankai;Yan Sen;Gu Dongming;Huang Shun(School of Architecture,Harbin Institute of Technology;Heilongjiang Provincial Key Laboratory of Building Energy Efficiency and Utilizatio;SINOPEC Shanghai Engineering Co.,Lt;China Railway Siyuan Survey and Design Group Co.,Ltd)
出处 《制冷与空调》 2018年第8期83-88,共6页 Refrigeration and Air-Conditioning
关键词 空气源热泵 试验研究 墙面板 除霜 air source heat pump experimental study wall panel defrosting
  • 相关文献

参考文献3

二级参考文献12

  • 1肖益民,付祥钊.户式空气源热泵地板供暖系统实测分析[J].湖南大学学报(自然科学版),2009,36(S2):14-18. 被引量:6
  • 2刘丽波.电热膜采暖应用中几个问题的探讨[J].林业科技情报,2007,39(2):70-71. 被引量:3
  • 3李少斌.新型薄型供暖地板热工性能研究[D].北京:北京建筑工程学院,2008.
  • 4Kuwahara E, Kawamura T, Yamazaki M. Shorting the defrost time on a heat-pump air conditioner[J].ASHRAE Transaction, 1985,91 :20-29.
  • 5O'Neal D L, Peterson K T, Anand N K, et al. Refrigeration system dynamics during the reverse cycle defrost[J]. ASHRAE Transaction, 1989,95: 689-698.
  • 6Nutter DW, O'Neal D L, Payne W V. Impact of the suction line accumulator on the frost/defrost performance of an air-source heat pump with a scroll compressor[J]. ASHRAE Transaction, 1993,99:689-698.
  • 7O' Neal D L, Peterson K T, Anand N K. Effect of short-tube orifice size on the performance of an air source heat pump during the reverse-cycle defrost [J].Int J Refrig, 1991,14(7). 52-57.
  • 8中国建筑科学研究院.JGJ142-2004地面辐射供暖技术规程[S].北京:中国建筑工业出版社,2004
  • 9吴锦京,卢纪富,曾章传,魏新利,陈万仁,魏宗弟.空气源热泵直接地板辐射供暖运行模式实验研究[J].暖通空调,2010,40(1):71-74. 被引量:10
  • 10方乐平.燃气壁挂炉采暖的应用及经济性分析[J].科技信息,2010(33):56-56. 被引量:4