期刊文献+

双端直流配电网反时限电流方差保护方案 被引量:13

Inverse Time Current Variance Protection Scheme for Two-Terminal DC Distribution System
下载PDF
导出
摘要 电力电子技术的进步推动了直流配电技术的发展,但相较于交流配电网成熟的继电保护技术,直流配电网保护面临着速动性不足,传统保护方案不适用等一系列的挑战。因此,该文提出适用于双端直流配电网的反时限电流方差保护,以电流方差代替电流值作为故障判据,并利用电压加速因子加快故障切除,针对两侧保护装置整定值不一致可能导致保护误动的问题,引入电流微分方向判据,实现保护动作的选择性。该方法基于本地测量量,无需通信,动作速度快。 Progress in power electronic technology promotes development of DC distribution technology. However, compared to mature AC relay protection, DC distribution protection faces a series of challenges, such as lack of quickness, inapplicability of traditional scheme, etc. This paper presented an inverse time current variance protection scheme for two-terminal DC distribution system, using current variance instead of over-current as fault criteria and voltage acceleration factor to speed up fault clearance. To solve the problem that inconformity of two sides of protection equipment may cause malfunction of protection, the paper introduced current derivative as direction criteria to realize selectivity of protection. This scheme was based on local measurement and cleared fault without communication. Finally, validity of the proposed protection scheme was verified with PSCAD/EMTDC simulation.
作者 高仁栋 吴在军 范文超 窦晓波 胡敏强 吴文宣 GAO Rendongl;WU Zaijun;FAN Wenchao;DOU Xiaobol;HU Minqiang;WU Wenxuan(School of Electrical Engineering,Southeast University,Nanjing 210096,Jiangsu Province,China;Sate Grid Fujian Electric Power Co.,Ltd.,Fuzhou 350003,Fujian Province,China)
出处 《电网技术》 EI CSCD 北大核心 2018年第9期2849-2858,共10页 Power System Technology
基金 国家重点研发计划(2018YFB0904704) 国网福建省电力有限公司科技项目(52130414005k)~~
关键词 双端直流配电网 电流方差 电压加速因子 方向判据 two-terminal DC distribution system currentvariance voltage acceleration factor direction criteria
  • 相关文献

参考文献15

二级参考文献306

共引文献1656

同被引文献220

引证文献13

二级引证文献150

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部