摘要 水电厂自动发电控制(AGC)的投入对机组的安全稳定运行造成一定影响,通过划分机组振动区能够有效提高AGC的避振运行。为此,采用真机试验方法对250 MW混流式机组开展不同水头下的稳定性试验,将运行区域划分为禁运区、不推荐运行区、推荐运行区,并对AGC运行过程中的多种避振运行问题进行优化处理,包括机组有功梯度调节限值的设置、实时计算并上报调度机组联合振动区、给定有功负荷落在不推荐运行区等。结果表明,振动区的划分不仅有利于保障机组的安全稳定运行,且为调度中心的负荷调度调整提供了参考。 The automatic generation control (AGC) in hydropower plant may cause a series of safety operation problems. The avoidance vibration operation of AGC can be effectively improved by dividing the vibration zone. The stability tests of 250 MW Francis turbine under different water head were carried out. The operation range was divided into forbidden-running zone, non-recommended operation zone and running zone. The various avoidance vibration operation problems of AGC were optimized, which include setting the threshold of unit's active power gradient, real-time calculation and report of unit's joint vibration zone and given active power load within the non-recommended operation zone. The results show that the partition of unit's vibration zone can ensure the safe and stable operation of the unit, and provide reference for dispatch center adjusting load.
作者 乔亮亮 李晨坤 付亮 唐卫平 QIAO Liang-liang, LI Chen-kun,FU Liang,TANG Wei-ping(State Grid Hunan Province Electric Power Corporation Electric Power Research Institute, Changsha 410007, Chin)
出处 《水电能源科学》 北大核心 2018年第9期152-154,共3页 Water Resources and Power
基金 湘电自筹项目(XDKY-2016-020)
关键词 水电机组 AGC 稳定性 振动区 hydroelectric generating set AGC stability vibration area
  • 相关文献

参考文献4

二级参考文献35

共引文献59

同被引文献121

引证文献9

二级引证文献43

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部