摘要
本文通过对主排水泵站实际运行过程中遇到的平衡盘碎裂,电机过电流,等问题进行分析,分析产生这些问题的原因,得出结论,并提出合理的应对以及改进意见,通过这些分析解决了实际问题,并对我们主排水泵设计提供了设计指导。
By analyzing the problems which appear duringthe drainage pumping station works, we can get some useful conclusion to improve our designing plan. The problems includes crush of balance disks, overflow of electric current, and so on. After analyzing these problems, we finally solve them and provide adaptive design guidance to the main drainage pump.
作者
邓伟
DENG Wei(Minmetals Mining(Anhui)Engineering Co.Ltd,Hefei 230000,China)
出处
《世界有色金属》
2018年第12期241-241,243,共2页
World Nonferrous Metals
关键词
排水泵
气蚀
过电流
平衡盘
drainage pump
gas etching
overflow
balance disk