期刊文献+

精铸联体导向叶片的数字射线检测技术研究 被引量:3

Study on Digital Radiography Inspection Technology of Combined Guide Vanes by Investment Casting
下载PDF
导出
摘要 随着航空制造技术的发展,低压涡轮导向叶片均采用整体铸造结构,而多联体叶片形状复杂,分布多个空间角度凸台,检测难度极大。利用机械手数字射线检测系统,通过数字射线检测和传统胶片检测方法对比,确定多联体导向叶片数字射线检测的工艺可行性,实现了多联体导向叶片自动化全方位的检测,从而提高了检测效率。 With the development of aeronautical manufacturing technology, the integral casting structure is adopted for the low pressure turbine guide vanes. However, the shape of the combined vanes is complex, and many spatial angles and bosses are distributed on the vanes, so it is very difficult to detect the vane castings. In the paper, by using the digital radiography (DR) detection system with a manipulator, and by comparing the digital ray detection method and the conventional film detection method, the feasibility of the digital ray detection technology was verified for the combined guide vanes, and the automatically comprehensive detection was realized for the combined guide vanes, thus the detection efficiency was improved.
作者 王立丰 夏志风 张孝玲 杨飞 孙长波 WANG Li-feng;XIA Zhi-feng;ZHANG Xiao-ling;YANG Fei;SUN Chang-bo(Shenyang Aero-Engine Precision Casting Co.,Ltd.,Shenyang 110043,Liaoning,China)
出处 《铸造》 CAS CSCD 北大核心 2018年第9期810-814,共5页 Foundry
关键词 联体导向叶片 铸件 数字射线 检测技术 combined guide vanes casting digital radiography detection technology
  • 相关文献

参考文献4

二级参考文献25

  • 1李殿中,康秀红,夏立军,李依依.可视化铸造技术的研究与应用[J].铸造,2005,54(2):148-152. 被引量:28
  • 2Ron Pincu. Digital radiography and its advantages in field NDT inspections today [C]// 17th World Conference on Nondestructive Testing, Shanghai, China, 2008.
  • 3Pardikar R J. Digital radiography and computed radiography for enhancing the quality and productivity of weldments in components [C]// 17th World Conference on Nondestructive Testing, Shanghai, China, 2008.
  • 4Anthony Seibert J. Advances in computed radiography: dual-side readout [J]. Journal of the American College of Radiology, 2010, 7 (2) : 154-157.
  • 5黄东琴.航空发动机精密铸件射线CR工艺研究[D].南昌:南昌航空大学,2010.
  • 6Vuylsteke, Pieter Paul, Schoeters, et al. Method and apparatus for contrast enhancement. US 5805721 [P]. 1998-09-18.
  • 7Dr R Halmshaw, Dr JNA Ridvard. A review of digital radiological methods[J]. Brit J NDT, 1990,32(1) : 17.
  • 8X-ray real-time imaging for weld inspeetion: IIW Pro- gress Report[J]. Brit J NDT, 1986,28(2) :89--92.
  • 9X-ray real-time imaging for weld inspection: IIW 2nd Progress Report[J]. Brit J NDT, 1987, 29 (1) ; 22 -- 23.
  • 10X-ray real-time imaging for weld inspection: IIW 3rd Progress Report[J]. Brit J NDT, 1987,29 (6): 426-- 428.