期刊文献+

智能站合并单元采样方式问题探讨 被引量:4

Study on the Merging Unit Sampling Mode of Smart Substation
下载PDF
导出
摘要 智能变电站发展过程中,智能继电保护采样方式主要经历了"电子式互感器+合并单元"、"常规互感器+合并单元"、"常规互感器电缆常规采样"3种方式,其中"常规互感器+合并单元"的采样方式在目前的智能站中大量使用,针对此方式中合并单元的采样延时、插值同步等问题进行了分析探讨,明确了合并单元存在增加继电保护动作时间、同步异常易导致差动保护误动问题。将智能站改进为常规采样方式后,对继电保护可靠性和电网的稳定性均有较大的提升。 During the development of smart substation, modes of "electronic transformer+ merging unit", "conventional transformer+merging unit"and "conventional transformer+ routine cable sampling" have been adopted in relay protection sampling. The mode of"conventional transformer+ merging unit"is generally adopted in the smart substation at present. In this paper, in view of this sampling mode, time delay and interpolation-based time synchronization are analyzed. It is cleared that the merging unit is defective in relay protection action time delaying and the differential protection mal-operation if synchronizing abnormally. After the conventional sampling mode is adopted in smart station, the reliability of the relay protection and the stability of the power grid are greatly improved.
作者 白瑞 王亮 白雪婷 BAI Rui;WANG Liang;BAI Xueting(State Grid Shanxi Electric Power Research Institute of SEPC,Taiyuan,Shanxi 030001,China;Kunming University of Science and Technology,Kunming,Yunnan 650504,China)
出处 《山西电力》 2018年第4期19-22,共4页 Shanxi Electric Power
关键词 智能变电站 过程层 合并单元 延时 smart substation process layer merging unit time delay