摘要
对昆明市某地下式污水处理厂进行消防设计时需考虑的火灾危险性因素等进行了详尽分析,系统阐述了地下式污水处理厂消防设计的难点。通过调研国内类似工程的消防设计,结合相关设计规范及工程实际情况,提出了地下式污水处理厂消防设计简化方案,为我国地下式污水处理厂的消防设计提供参考。
Based on detailed analysis of risk factors in fire control design of an underground wastewater treatment plant in Kunming, the difficulties existing in fire control design of the underground wastewater treatment plant are systematically expounded. Through research of the fire control design of similar domestic projects, in combination with relevant design codes and practical situation, simplified fire control design schemes for underground wastewater treatment plant are proposed, providing reference for the fire control design of domestic underground WWTP.
作者
倪明
Ni Ming(Shanghai Municipal Engineering Design Institute 〈Group〉 Co.,Ltd.,Shanghai 200092,China)
出处
《净水技术》
CAS
2018年第9期4-9,共6页
Water Purification Technology
关键词
地下式污水处理厂
消防设计
案例分析
underground wastewater treatment plant fire
control design
case analysis