摘要 采用蒙特卡罗方法与响应面法相结合的方法,分析了三种常见钢结构变电构架在设计荷载作用下的承载力可靠度。结果表明:在设计荷载作用下,三种变电构架承载能力的可靠度均随着构件损伤程度的增大而降低。当构件损伤程度较轻时,整个变电构架的结构可靠度并不明显降低,此时整个结构仍具有良好的工作性能;随着构件损伤程度的增大,结构的可靠概率明显降低,结构很快就变得不可靠,此时须立即修复或更换受损构件,以保证变电构架结构整体的安全性。 The united arithmetic method of Monte Carlo method and response surface method were adopted to compute the reliability of steel substation structures under the design loads.The results show that the reliability of the bearing capacity of the three kinds of substation structures decrease with the increase of dent-damage degree.However,minor dent-damage of the members can hardly reduce the structure' s reliability,and the structure has well working performance.Serious dent-damage degree of the members reduces the reliability probability of the structure obviously,and the structure will soon become unreliable,and the damaged members must be repaired or replaced immediately to ensure the safety of the whole substation structure.
作者 吕中宾 张猛 Lu Zhongbin;Zhang Meng(State Grid Key Laboratory of Transmission Line Galloping Control Technology(State Grid Henan Electrie Power Corporation Electric Power Research Institute),Zhengzhou 450052,China;School of Civil Engineering,Zhengzhou University,Zhengzhou 450001,China)
出处 《建筑结构》 CSCD 北大核心 2018年第17期118-122,共5页 Building Structure
基金 中国博士后科学基金资助项目(20090450935) 国网河南省电力公司科技专项(2016-01-06)
关键词 变电构架 凹陷损伤 极限承载力 概率灵敏度 可靠度分析 substation structure dent-damage ultimate bearing capacity probabilistic sensitivity reliability analysis
  • 相关文献

参考文献4

二级参考文献23

  • 1舒赣平,孟宪德,陈绍礼.钢框架的高等分析与设计[J].建筑结构学报,2005,26(1):51-59. 被引量:29
  • 2李天,袁征,郑德乾,马哲芳.应用高等分析理论分析人字形电力构架[J].郑州大学学报(工学版),2006,27(1):15-18. 被引量:5
  • 3王柯,李丰,李天.多层钢框架二阶弹性内力分析[J].结构工程师,2006,22(4):13-17. 被引量:4
  • 4Padula J A. A Simplified Method for Estimating the Load-Shortening Behavior of Damaged Tubular Columns [ D ]. Bethlehem: Lehigh University, 1999.
  • 5沈祖炎,董石麟,陈学潮.空间网格结构论文集[C].上海:同济大学出版社,1991.
  • 6CHEN W F,ATSUTA T(周绥平译).梁柱分析与设计(第一卷):平面问题特性及设计[M].北京:人民交通出版社,1997.
  • 7中华人民共和国建设部.GB50205-2001钢结构工程施工质量验收规范[S].北京:中国计划出版社,2002.
  • 8ELLINAS C P. Damage on offshore tubular bracing members. Proceedings IABSE Colloquium on Ship Collosion with Bridge and Offshore Structures [C], 1983:253-261.
  • 9DUAN L. Stability Analysis and Design of Steel Structures[D]. Purdue University, 1990.
  • 10DUAN L, CHEN W F, LOH J T. Behaviour and strength of damaged tubular members ,in offshore structures[A]. Proceedings of the Second International Offshore and Polar Engineering Conference[C]; 1992: 14-19.

共引文献5

同被引文献2

引证文献1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部