摘要 目的了解近年来患者起搏器囊袋感染的危险因素。方法回顾性分析2011年1月至2016年9月年在浙江省人民医院行永久性心脏起搏器植入的863例患者,统计患者病历资料、起搏器和起搏器手术情况、感染及其处理情况,并分析起搏器囊袋感染的相关危险因素。结果863例患者中发生起搏器囊袋感染共27例,平均年龄(68.3_+10.0)岁,21例均为男性,合并高血压、糖尿病、房颤等较多基础疾病;感染主要发生于术后中期(1~12个月)和远期(〉24个月)。Logistic回归分析表明,起搏器囊袋感染与男性(OR=8.288,95%C1:2,830~24.275)和心力衰竭(OR=3.280,95%CI:1.485-7.248)相关。感染病原菌多为葡萄球菌,囊袋感染直接行装置拔除加囊袋清创的有效率稍高于行抗感染治疗或囊袋清创,抗菌谱同时覆盖葡萄球菌和肠杆菌的抗感染药物效果较好。结论起搏器囊袋感染发生率不低,男性和心力衰竭是感染发生的危险因素。 Objective To investigate the risk factors of patients with pacemaker pouch infection (PPI). Methods From January 2011 to September 2016, a total of 863 cases performed pacemaker implantation in Zhejiang Provincial People's Hospital were enrolled. The medical history, pacemakers, pacemaker implantation, PPI and its treatment were collected, while the risk factors related to pacemaker pouch were analyzed. Results Among 863 cases, 27 cases occurred PPI. The average age of PP] patients was (68.3+10.0) years old, and 21 cases were male. Most PPI patients complicated underlying diseases like hypertension, diabetes and atrial fibrillation. Infection mainly occurred in the medium (1-12 months) and long term(〉24 months) periods after implantation. The logistic regression analysis showed that PPI occurred more often in males(OR=8.288, 95%CI: 2.830-24.275) and patients with heart failure (0R=3.280, 95%C1: 1.485-7.248). The main pathogens were Staphylococcus. Direct removal of pacemaker plus pouch debridement was the slightly more effective than anti-infective therapies or pouch debridement in PPI cases, and antibiotics with the spectrum covered both Staphylococcus and Enterobacter got better results. Conclusions The incidence rate of PPI is not low. Male and heart failure are the risk factors for the infection.
作者 薛奇 邵红 邹海 马元 Xue Qi;Shao Hong;Zou Hai;Ma Yuan(Department of Cardiology,Zhejiang Provincial People "s Hospital,People Is Hospital of Hangzhou Medical College,Hangzhou 310014,China)
机构地区 浙江省人民医院
出处 《国际流行病学传染病学杂志》 CAS 2018年第4期239-241,共3页 International Journal of Epidemiology and Infectious Disease
基金 浙江省医药卫生科技计划(2018KY258) 浙江省自然科学基金青年基金(LQ18H020003)
关键词 感染 心脏起搏器 Infection Pacemaker
  • 相关文献

参考文献4

二级参考文献15

  • 1韩群霞,满莉.心脏起搏器植入术引起囊袋医院感染报道[J].中华医院感染学杂志,2004,14(8):869-869. 被引量:4
  • 2Bailey SM,Wilkoff BL. Complications of pacemakers and defibrillators in the elderly[J]. Am J Geriatr Cardiol, 2006,15 (2): 102.
  • 3Love C J, Wilkoff BL, Byrd CL et al. Recommendations for extraction of chronically implanted transvenous pacing and defibrillator leads: indications, facilities, training. North American Society of Pacing and Electrophysiology Lead Extraction Conference Faculty. Pacing Clin Electrophysiol, 2000;23:544.
  • 4Darouiche RO. Trealment of infections ass iated with surgical implants. N Engl J Med, 2004;350:1422.
  • 5Baddour LM, Epstein AE, Erickson CC et al. Update on cardiovascular implantahle electronic device infections and their management: a scientific statement from the American Heart Association. Circulation, 2010;121:458.
  • 6Wilkoff BL, Love C J, Byrd CLet al. Transvenous lead extraction: Heart Rhythm S icty expert consensus on facilities, training, indications, and patient management: this document was endorsed by the American Heart Association (AHA). Heart Rhythm, 2009;6:1085.
  • 7Greenspon AJ, Patel JD, Lau E et al. 16-year trends in the infection burden for pacemakers and implantable cardi 111 the United States 1993 to 2008. J Am Coil Cardiol, 2011;58:1001.
  • 8S.M. Kurtz, J.A. Ochoa, E. Lau et al.Implantation trends and patient profiles for pacemakers and implantable cardioverter defibrillators in the United States: 1993-2006.Pacing Clin Electrophysiol, 2011;33: 705.
  • 9Arnold J. Greenspon, Jasmine D. Patel, Edmund Lau et al. Trends in Permanent Pacemaker Implantation in the United States From 1993 to 2009: Increasing Complexity of Patients and Procedures. J Am Coil Cardiol,60:1540.
  • 10S.M. Kurtz, J.A. Ochoa, E. Lau et al.Implantation trends and patient profiles for pacemakers and implantable cardioverter defibrillators in the United States: 1992-2006. Paeing Clin Electrophysiol, 33:705.