摘要
以30万t/a离子膜法烧碱装置采用国产2. 5万t/a离子膜电解装置为例进行设定,整流机组参数的确定包括一次侧电压、直流电压、直流电流、机组数量、等效整流相数,整流柜参数、导电排参数等。
Parameters of the rectifier set for a 300 kt/a ion-exchange membrane caustic soda were determined by taking the rectifier system for a domestic 25 kt/a ion-exchange membrane soda project as an example, including primary side voltage, DC voltage, DC current, number equivalent rectifying phase number, rectifier cabinet parameters, conducting bar parameters and project caustic of unit, SO on.
作者
孙利俊
耿庆鲁
SUN Lijun;GENG Qinglu(Inner Mongolia Elion Chemical Industry Co.,Ltd.,Erdos 014300,China;Dezhou Shihua Chemical Co.,Ltd.,Dezhou 253007,China)
出处
《氯碱工业》
CAS
2018年第9期6-8,11,共4页
Chlor-Alkali Industry
关键词
离子膜法烧碱
整流变压器
整流柜
直流电压
直流电流
整流相数
ion-exchange membrane caustic soda
rectifier transformer
rectifier
DC voltage
DCcurrent
number of units
rectifying phase number